8. RX LED
Function
: Edits the BUSY indicator color.
Available Values
: Individual adjustments of the Red,
Green, and Blue color hue may be performed, on a nu-
merical scale of “000” to “255.” See page 46 for details.
Default Setting
: Green (R000, G111, B000)
9. TX LED
Function
: Edits the TX indicator color.
Available Values
: Individual adjustments of the Red,
Green, and Blue color hue may be performed, on a nu-
merical scale of “000” to “255.” See page 46 for details.
Default Setting
: Red (R111, G000, B000)
10. EMG LED
Function
: Edits the Emergency lamp color.
Available Values
: Individual adjustments of the Red,
Green, and Blue color hue may be performed, on a nu-
merical scale of “000” to “255.” See page 46 for details.
Default Setting
: White (R127, G127, B127)
11. Alert LED
Function
: Edits the Weather Alert lamp color.
Available Values
: Individual adjustments of the Red,
Green, and Blue color hue may be performed, on a nu-
merical scale of “000” to “255.” See page 46 for details.
Default Setting
: Green (R000, G127, B000)
12. TEMP LED
Function
: Edits the Over Heating lamp color. This is a
display seen when the temperature exceeds the threshold
set via the “
TEMP Set
” setting (see page 58).
Available Values
: Individual adjustments of the Red,
Green, and Blue color hue may be performed, on a nu-
merical scale of “000” to “255.” See page 46 for details.
Default Setting
: Light Blue (R127, G000, B127)
2. S
OUND
1. Beeper
Function
: Select the Keypad beeper tone.
Available Values
: On/DTMF/Off
Default Setting
: On
On:
Enables the keypad beeper.
DTMF: Enables the keypad beeper with DTMF tones.
Off:
Disables the keypad beeper.
2. Bell
Function
: Enables/disables the Bell Ringer function.
Available Value
s: On/Off
Default Settin
g: Off
M