FT-2000
Operating Manual
Vertex Standard Co., Ltd.
108
tyP1: You may enter the CW message from a front panel’s Function Keys (require the
optional DMU-2000 Data Management Unit).
tyP2: You may enter the CW message from the CW keyer.
024 tEy CW MEM5
Function: Permits entry of the CW message for message register 5.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from a front panel’s Function Keys (require the
optional DMU-2000 Data Management Unit).
tyP2: You may enter the CW message from the CW keyer.
GENERAL Group
025 GEnE ANT SEL
Function: Sets the method of antenna selection.
Available Values: bAnd/rEG
Default Setting: bAnd
bAnd:
The antenna is selected in accordance with the operating band.
rEG:
The antenna is selected in accordance with the band stack (different
antennas may be utilized on the same band, if so selected in the band stack).
026 GEnE BEP LVL
Function: Sets the beep level.
Available Values: 0 ~ 255
Default Setting: 50
027 GEnE CAT BPS
Function: Sets the transceiver’s computer-interface circuitry for the CAT baud rate to
be used.
Available Values: 4800/9600/192H(19200)/384H (38400) bps
Default Setting: 4800 bps
028 GEnE CAT TOT
Function: Sets the Time-Out Timer countdown time for the CAT command input.
Available Values: 10/100/1000/3000 msec
Default Setting: 10 msec