Function: Sets the delay time for the AGC MID mode of the Main band (VFO-A)
receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
004 AGc MID HLD
Function: Sets the hang time of the AGC peak voltage for the AGC MID mode of the
Main band (VFO-A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 0 msec
005 AGc SLW DLY
Function: Sets the delay time for the AGC SLOW mode of the Main band (VFO-A)
receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 2000 msec
006 AGc SLW HLD
Function: Sets the hang time of the AGC peak voltage for the AGC SLOW mode of the
Main band (VFO-A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 0 msec
DISPLAY Group
007 diSP COLOR
Function: Selects the Display color when the optional Data Management Unit
(DMU-2000) is connected.
Available Values: bL1/bL2/bL3/ub1/ub2
bL1: COOL BLUE
bL2: CONTRAST BLUE
bL3: FLASH WHITE
ub1: CONTRAST UMBER
ub2: UMBER
Default Setting: bL1 (COOL BLUE)
Advice: If the optional DMU-2000 Data Management Unit is not connected, this