FT-2000
Operating Manual
Vertex Standard Co., Ltd.
105
adjustment has no effect.
008 diSP DIM MTR
Function: Setting of the meter brightness level when “DIM” is selected.
Available Values: 0 ~ 15
Default Setting: 4
009 diSP DIM VFD
Function: Setting of the frequency display brightness level when “DIM” is selected.
Available Values: 0 ~ 15
Default Setting: 8
010 diSP BAR SEL
Function: Selects one of three parameters to be viewed on the Tuning Offset Indicator.
Available Values: CLAr/C-tn/u-tn
Default Setting: C-tn
CLAr: Displays relative clarifier offset.
C-tu: Displays relative tuning offset between the incoming signal and transmitted
frequency.
u-tn: Displays the peak position of the VRF or µ-TUNE filter.
Note: The µ-TUNE filter is option.
011 diSP PK HLD
Function: Selects the peak hold time of the Sub (VFO-B) receiver’s S-meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
012 diSP RTR STU
Function: Selects the starting point of your rotator controller’s indicator needle.
Available Values: 0/90/180/270 °
Default Setting: 0 °
Advice: If the optional DMU-2000 Data Management Unit is not connected, this
adjustment has no effect.
013 diSP RTR ADJ
Function: Adjusts the indicator needle precisely to the starting point set in menu item