19 CUCINA 36P VERONA 07-2011 BOOKLET for HenryRev. o4
In case of a fixed connection to junction box, a
1/8” open gap two way switch
must be used before the Junction Box.
NOTE: Install a suitable flexible cord, through Junction Box on rear of
appliance, to oven electrical terminal block. Follow fig. 15A and fig. 15B, page
30 for proper electrical connection of flexible cord to appliance terminal block.
Attention: always refer to product label for correct electrical power rate, before
proceeding with electrical connection.
ELECTRICAL CONNECTION ON TERMINAL BLOCK
1. For Double phase connection 120/240V~ 60 Hz for Canada, fig. 15A,
page 30:
On position n° 1, connect the Black electrical supply wire (hot wire or L1),
positions n° 1 and 2 are bridged together,
position n° 3, connect the Red electrical supply wire (hot wire or L2),
positions n° 4 and 5 are bridged together,
position n° 5, connect the White electrical supply wire (neutral wire or N),
to position n° 6, connect the Green ground electrical supply wire.
2. For Double phase connection 120/208V~ 60 Hz for US, fig. 15B, page 30:
On position n° 1, connect the Black electrical supply wire (hot wire or L1),
positions n° 1 and 2 are bridged together,
position n° 3, connect the Red electrical supply wire (hot wire or L2),
positions n° 4 and 5 are bridged together,
position n° 5, connect the White electrical supply wire (neutral wire or N),
to position n° 6, connect the Green ground electrical supply wire.
CAUTION:
The flexible cord must be held tight by the cord lock, in such a way that it may
not be pulled out. The flexible cord path must not be in proximity or in contact
with hot surfaces that may damage the cord itself.
GROUNDING
IMPORTANT:
Local codes might vary, installation, electrical connections and
grounding must comply with all applicable local codes.
WARNING:
This appliance requires a ground connection for your protection
against shock hazard and should be connected directly into a properly
grounded receptacle.