15 CUCINA 36P VERONA 07-2011 BOOKLET for HenryRev. o4
INSTALLATION INSTRUCTIONS
SPECIAL WARNING:
ONLY QUALIFIED AND AUTHORIZED PERSONNEL SHALL INSTALL OR
SERVICE THIS RANGE.
READ “SAFETY INSTRUCTIONS” IN THIS BOOK BEFORE USING
RANGE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE,
MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY
OR PROPERTY DAMAGE, AND SO THE MANUFACTURER WILL NOT BE
RESPONSIBLE.
This appliance must be installed in accordance with the manufacturer’s
installation instructions and local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the U.S.A., and
current CAN/CSA B149.1 Natural Gas and Propane Installation Code.
CLEARANCE DIMENSIONS
Range may be installed with zero inches clearance adjacent to (against)
combustible construction at the rear and on the sides below the rangetop. For
complete information in regard to the installation of wall cabinets above the
range and clearances to combustible wall above the cooking top see the
installation drawing fig. n° 12 and 13, pages 28 & 29. For Safety
considerations do not install a range in any combustible cabinetry which is not
in accord with the installation drawings.
NOTE:
42 inch dimension between cooking top and wall cabinet shown on
illustration does not apply to ranges with an elevated oven. The
“A” 42 inch
dimension may be reduced to not less than 36 inches when the wall cabinets
in a domestic home are protected with fireproof materials in accordance with
American National Standards
– National Fuel Gas Code. “B” has to be not
less than 8 inch from the top surface to a vertical side combustible wall.
The “C” dimension is the total of product’s width plus 1”.
To eliminate the risk of burns or fire by reaching over heated surface units,
cabinet storage space located above the surface units should be avoided.
If cabinet storage is to be provided, the risk can be reduced by installing a
range hood that projects horizontally a minimum of 5 inches beyond the
bottom of the cabinets.