1.1.7
2.3 Preventive maintenance
-
The maintenance team shall carry out on an annual basis the following operations:
-
Cleaning of the controller,
-
Verification of the general condition of the controller
-
Verification of the emergency stop button.
-
The maintenance team shall carry out the following operations:
- Switch off the system completely,
- Unplug all connectors connected to the controller, then proceed with cleaning and
verification of the general condition:
- Gently apply compressed air (dry, oil-free air) inside the controller to remove dust that has
gathered.
CAREFUL: you could damage electrical connections if the compressed air pressure is too
great,...
- Check that accessible electrical connections are properly tightened,
- Check that there are no visible anomalies (overheated, blackened components, leads
or connections), or abnormal noise.
3-Basic principle of operation
The controller controls the upward and downward travel of hoists and stop.
When at stop the absence of voltage causes the brake to close.
Movement will only take place for as long as the Start button is held down.
3.1- Light signaling (Figure 1)
1) Power
3.1- Signalisation lumineuse (
Figure 1)
1) Présence tension de commande
Figure 1