34. Status assigned from the washing machine. 

Related information aboutthe device

will not be

displayed until it is connected from the 

device to the system. 

 

35. Status of the elevator controller. 

You can enable/disable the elevator control function. 

Note: This feature only works if an elevator control module is installed on the system. 

 

36. Setting the security parameters of the input 

unit (depending on the type). 

 

37. Tampéru,

 (protective contact when the cover is opened

 illegally) after

activation of this function, a security 

contact will be activated in the input station , tamp

é

r and if someone tampers with the entrance

station, an alarm 

will be triggered. The room number must also be set to receive the tampee alarm. 

 

38. Check the condition of the door. 

If this function is enabled, the system checks the door status after the longest opening time 

Door. Set "Magnetic Contact Type" according to door lock type 

(Normally open or Normally closed). Set "Longest opening time". Once the door is open, the entrance 

station will check their status for the longest opening time set. 

If the door is not closed after the longest opening time set, a beep will sound from the entrance station. 

 

39. Adjust the volume of the bell speaker. 

You can adjust the volume from 10% to 100% as needed. 

 

40.Adjust the angle of view. 

You canset the angle of viewfor

the

entry station. Press the menu to set the angle ofview

from the

entry 

station. Touch thelocationon the screen where it wants

to

get closer. 

Press the tracking icon

to exit. Finally, tap the return icon in the upper-left corner of the screen and 

press the confirm settings icon to save the settings. Whenitrings fromtheentrance station,

a set 

image

appears. 

 

41. Set a password to configure a door lock 

The password can be up to 8 digits, the first digit must not be 0 

 

42. Setup mode. 

It is turned on by default. If enabled, you can set "Room Address" and "Floor" for monitors on the network. 

If it is turned off at all entry stations 

network, you will not be able to change the address of any monitor. If you don't want users to accidentally 

change the address of your monitors, turn off this feature on all input stations after installation. 

 

43.System settings 

 

N.o

Settings 

Items 

Item 

Explanation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set up sound 

Still 

 

 

 

 

 

Ringtone Sound 

 

 

Off by default. If enabled, the monitor will not 

ring when it rings. 

 

Repeat ringtone: If you turn off the monitor 

when 

ringing only once. 

 

Door opening ringtone: Set the ringtone for 

calls from vst. Station.  

Summary of Contents for Veria 8276B

Page 1: ...VERIA User s guide Videophone Model Veria 8276B Please read this manual carefully before use and keep it in case of further need...

Page 2: ...System settings 13 19 Setting the password 13 20 Password protection list input stations 13 21 Setting the address of the room 14 22 Set the monitor name 14 23 Setting the name of the entry station 1...

Page 3: ...conditions may result in damage fromthe device injury to the property orfire Do not bend or unplug the power cord from the mains by force If it is damaged there is a risk of fire or electric shock Do...

Page 4: ...2 Features and description of the device Name 1 Speaker 2 Lcd 3 Microphone 4 Button menu 5 SD Card Slot 6 Back button 7 Left button 8 Right button 9 Call button 10 Track button 11 Open button...

Page 5: ...ents and contact your dealer immediately Package contents Monitor Wall mount Terminals Screw M3x20mm 2pcs Dowle 2pcs Power adapter 5 Installation Note For trouble free videophone operation please obse...

Page 6: ...specification N O Item Content 1 Display Colour 7 LCD 800 x 400 2 Intercom type Hands free 2 Connection 2 wire 4 Sound distortion Less than 3 5 Frequency response 400 3 5K 6 Wire length Maximum 200 me...

Page 7: ...ntacts 1 Power contact DC24V 1A Max 2 SW1SwitchNo To adjust the contact of the2 wirebus Setting Set the last monitor on the2 wirebus to set the SW1 to the ON position Other SWmonitorsto off position 3...

Page 8: ...6 Connectivity options 230V 24V DC adapter 1 1xmonitor 1x access station...

Page 9: ......

Page 10: ...2x monitor 1x entry station 4x monitor 2x entry station 5x monitor 1x entry station...

Page 11: ...stedon the screen Icon Function Accept Hang Volume Buy Photograph Buy Video Unlock gate or door View or hide icons on the screen Press to answer the call and talk to the visitor After the call is over...

Page 12: ...Call history Press the recent icon in the call menu to view historie Press from the list of anycall to makea call 4 Favorites Pressing andsubduingany call in history will appear on the screen The icon...

Page 13: ...on on themain menuto go tothe videolist and press the selected video to start it by pressing the icon or viewing theprevious or subsequent video recording Pressing anddeleting theselectedphotoor video...

Page 14: ...ote 1 The DVR only records video recording without sound 2 A minimum 2G SD card is required to support DVR function 16 GB recommended or 32 GB SD card 3 If motion is detected it is recorded at normal...

Page 15: ...ps restart the monitor and go to settings After restarting the monitor a password is not required for the first entry into the settings Go to the Password Protection menu and set your password as need...

Page 16: ...tton address is not set in the same way as the address of the target monitor the monitor can monitor the input station but the input station cannot call the monitor 28 Private equipment If this featur...

Page 17: ...set a beep will sound from the entrance station 39 Adjust the volume of the bell speaker You can adjust the volume from 10 to 100 as needed 40 Adjust the angle of view You canset the angle of viewfort...

Page 18: ...ss Low Normal High Adjust the brightness of the screen 5 Alarm clock Set an alarm Alarm volume Set 10 100 Alarm 1 2 3 4 5 6 You can set each alarm separately Alarm status Turn the alarm function on of...

Page 19: ...try stations View Edit You must enter the correct password to enter the input station settings Cancel Button address to set the target address of button calls to the input station Private device If en...

Page 20: ...m Update the program Note In a standby or DVR calendar the device will be in screen saver state if no operation is performed within 4 hours Warranty SAFE HOME europe s r o as a supplier guarys to the...

Page 21: ...Website www veria eu SAFE HOME europe s r o reserves the right to modify and change product specifications without notice All materials are carefully inspected but the company SAFE HOME europe s r o i...

Reviews: