Sign Case
Give us your thoughts
36
PCMS Operations, Safety & Maintenance V2
Ver-Mac 2019
Figure 6 – Hardware tightening on a PCMS-3812PRO Series mast lock
10.3 Photocells
CAUTION
Dust and grime accumulation can obstruct the correct functioning
of external photocells.
Photocells detect the ambient light conditions and the brightness of the sign display
adjusts in consequence.
External photocells are located on the junction box underneath the solar panels or on
the left outside side wall of the sign case.
10.4 Radar Device
A speed radar device is attached directly to the underside of the sign case.
10.5 Sign Display
Before putting your PCMS into operation, it can be a good idea to run a pixel text and
verify that all display cards for the signboard are functioning.
Accessing the pixel test varies, depending on the software that controls the signboard.
Unit software
Steps
Quickstep
Login
[F4] Utilities
[F3] Brightness
[F5] Test
Signcore
Login
[4] Setup
[4] Tests
[1] Chessboard
Touchscreen
Login
Toggle Menu
Option
Pixel Test
Chessboard
10.6 Signboard Exterior Periodic Maintenance
Item
Function Required
Before
Every Use
3 Months 12 Months
Signboard Exterior
Main Harness
Crank the signboard up a little and check
main harness cables for wear
Make sure the cable lies loosely on the
battery boxes (not squeezed between sign
case and battery box, not caught in
anything or dragging on the ground)
•
Sign Case
(Outside)
Check all reflectors at top of case
(in place, unbroken)
Replace as needed
•
Check door
(closed and undamaged)
•
•
Check functioning of dashpot door closers
that hold the face open Replace if broken
•
Check condition of all rubber T-latch
clamps
(tight, not cracked or loose)
•
•
Summary of Contents for PCMS-1500