14
temperature
08:FL
Defines valid minimum setting/value for external/floor
temperature.
09:FL
Defines valid maximum setting/value for external/floor
temperature.
10:SE
Sensor selection. 00=Room sensor, 01=Floor sensor,
02=Both, combination mode. Set active sensor(s) according to
installation instructions.
11:CL
Clock. NO=No clock, thermostat will run in constant
temperature mode, 12h=12 hour clock with AM/PM, 24h=24
hour clock without AM/PM displayed. If either 12h or 24h is
active, event mode will also be activated.
12:DF
Default display of temperature: set or measured
temperature. 00=display measured temperature, 01=display set
temperature.
Leave all buttons for 10 seconds to save all settings and return
to normal operation mode. The ON/OFF button cancels and
exits the settings menu.
6.3. Event mode settings