21
Before installing the thermostat
Determine whether the heated floor shall be controlled by
using the room or floor sensor. For guidance, see table 1. Both
sensors can be set active. The room sensor will then be the
primary sensor, and the floor sensor can function as a
temperature limitation sensor, protecting the floor from
overheating. Please see user manual for further details.
The thermostat should be positioned approx. 1.6 m above the
floor. If the room sensor is used, the thermostat must be
positioned so that air freely can flow through the thermostat
chassis. Avoid placing the thermostat in places where it will be
exposed to direct sunlight or draught. Make sure that the
heating cable’s cold lead reaches the planned position of the
thermostat.
If installing floor sensor: Start by following the instructions in
section 1. For installation with room sensor only: Proceed
directly to section 2.
IMPORTANT: All wiring to be in accordance with the current
I.E.E regulations, or appropriate standards of your country and
MUST be installed by a suitably qualified person.