background image

 

13

Head Office:

 Fleming Way, Crawley, West Sussex RH10 9YX

Tel: 01293 526062    Fax: 01293 551188

Internet site at: www.vent-axia.com

 

 

VENT-AXIA SALES CENTRES 

 

ENGLAND & WALES NATIONAL CALL CENTRE 

Newton Road, Crawley 
West 

Sussex 

   

RH10 

9JA 

   

 
Telephone: 01293 530202  

 

 

REPUBLIC OF IRELAND 

Fax:           01293 565169  

 

 

Vent-Axia Ventilation Ltd. 

 

     921 

Western 

Road 

Industrial 

Estate 

 

 

    Naas 

Road, 

Dublin 

12. 

 

 

 

 

     Telephone: 

(01) 

450 

4133 

 

 

 

 

 

 

Fax:            (01) 450 4570 

 
 
 

Did you find these instructions easy to use? 

 

We value your comments, contact us via: 

 

Email: [email protected] 

 
 

 

The Vent-Axia Guarantee 

 

Applicable only to products installed and used in the United Kingdom. For details of the Guarantee outside of the 
United Kingdom contact your local supplier. 
 
Vent-Axia guarantees this product for two years from the date of purchase against faulty material or workmanship. 
In the event of any part being found to be defective, the product will be repaired, or at the Company’s discretion the 
product will be replaced without charge, provided that the product: 
 

1).  Has been installed and used in accordance with the instruction given with each unit. 
2).  The electricity supply complies with the rating label. 
3).  Has not been misused, neglected or damaged. 
4).  Has not been modified or repaired by any person not authorised to do so by Vent-Axia. 

 

IF CLAIMING UNDER THE TERMS OF THE GUARANTEE 

 

Please return the complete product, carriage paid to your original supplier by post or in person. Please ensure that it 
is adequately packed and accompanied by a letter clearly marked ‘Guarantee Claim’ stating the nature of the fault 
and providing proof of the date and source of purchase. 

 

 

As part of the policy of continuous product improvement Vent-Axia reserve the right to alter specifications without notice 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

42 

57 

67 

          0608 

Summary of Contents for Air Minder Plus

Page 1: ...ABC WHOLE HOUSE HEAT RECOVERY UNIT Installation Connection and set up Instructions READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS...

Page 2: ...applications may require the installation of sound attenuation to achieve the sound levels required The unit must not be connected directly to a Cooker Hood or Tumble Dryer The Condensate Waste pipe...

Page 3: ...ONTROLLER Carton 2 8 TWO FAN BLOWER UNITS 9 TWO INLETS CARTON 2 ITEM 8 2 off ITEM 9 2 off A PREPARATION 1 Remove the contents from Carton 1 2 Remove the Air Filters from the main body 3 Release the si...

Page 4: ...on the other side of the Base Housing Inlet Item 9 Inlet Item 9 Fan blower unit Item 8 Fan blower unit Item 8 Electrical control box Ensure the Fan Units Item 8 are on either side of the Electrical Co...

Page 5: ...diagram below for loft or ceiling mounting Condensate connection Condensate connection Roofing joist Fit assembled 5 angled brackets Ceiling joist Fit assembled 5 angled brackets Loft mounting Ceiling...

Page 6: ...ns in the Tubing Note Ensure that units are installed with a 5 fall towards the condensate drain point 2 Connect the tubing Item 2 to Drain Elbow and secure into position with a Clip Band Align the el...

Page 7: ...tersink at the top of the slots provides permanent fixing Fixing Slots CONTROLLER 1 The 4 core SELV cable is wired to the controller terminals in the following order 2 Replace the Controller s front c...

Page 8: ...Low 90 m3 h Med 120 m3 h Med 140 m3 h Med 160 m3 h Med 180 m3 h High 200 m3 h High 230 m3 h High 270 m3 h High 290 m3 h AM PLUS 375 House Volume 400m3 466m3 555m3 600m3 Low 90 m3 h Low 100 m3 h Low 12...

Page 9: ...our will remain on and the Minutes will start to flash G 4 Setting the Minutes Press the or V Key to set the Minutes Press the Set Key the Minutes will remain on and the display will scroll to the nex...

Page 10: ...scribed in the Fitting and Wiring information Air Minder Plus 290 rate numbers and corresponding Airflow rates Nominal setting shown bold Air Minder Plus 375 rate numbers and corresponding Airflow rat...

Page 11: ...ng shown bold v v SET R u n n i n g T i m e 0 0 0 2 0 v v SET I n t a k E x h a 1 2 u s t 1 2 B B e House size 1 Low 1 60 Medium 5 120 Boost 3 80 4 90 5 120 6 140 7 160 8 180 9 200 House size 2 Low 2...

Page 12: ...s not permitted a link must be fitted between the JP 200 terminals on the HRU Control Panel When this link is in position and the external air temperature drops below 1 C the summer bypass will open a...

Page 13: ...against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s discretion the product will be replaced without charge pro...