T-10
Part #1169256
09/2008
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
Compressor will not
start, condenser
fan motor running
- unit hot (power to
compressor)
Defective overload relay
Replace the overload relay.
Compressor motor rocked
Replace the refer unit.
Defective capacitor
Replace the capacitor.
Defective PTC relay
Replace the PTC relay.
Compressor starts
but doesn’t run.
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings and
capillary
Replace the refrigeration unit.
Defective overload relay
Replace the overload relay.
Compressor
runs but cabinet
temperature warm.
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refrigeration unit.
Defective drainage
Make sure the drain hose is not kinked or clogged.
Defective temperature sensor Replace the temperature sensor.
Poor air fl ow
Make sure nothing is sitting in front of the evaporator.
Defective control board
Replace the control board.
Defective door seal
Make sure the vend fl ap and gasket are not open or damaged.
Defective heat exchange on
condenser/ Blocking air fl ow
by dust, lint or fi n damage
Clean the surface of the condenser fi ns or straighten the bent fi ns.
Evaporator frosted
over
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refer unit.
Defective drainage
Make sure the drain hose is not kinked or clogged. Re-install hose correctly if
kinked or clogged.
Defective temperature sensor Replace the temperature sensor.
Defective control board
Replace the board.
Poor sealing
Check gasket, vend fl ap, and permagum on the bulkhead.
Product freezing up
(too cold)
Temperature setting too low.
Adjust set point in control board.
Defective temperature sensor Replace the temperature sensor.
Defective control board
Replace the board.
Excessive noise
Fan blade hitting shroud or
loose fi tting
Replace the fan blade or re-install correctly.
Defective fan motor
Re-install or replace the motor.
Defective compressor
Replace the refrigeration unit.
Referigeration base deformed Re-install or replace the base and plastic trim.
Drain pan over fl ow Poor sealing
Make sure the vend fl ap closes correctly and the gasket is sealing.
Evaporation board (wick) dirty Clean or exchange the evaporation board.
Drain hose falls out from the
stud of drain pan.
Install hose correctly .
Defective condenser fan
motor
Replace the motor.
Abnormal amount of water
goes into the pan at one time
Throw out the water and check periodically to make sure the problem is not
still occurring.
Heater
Heater will not
run even at the
specifi c ambient
temperature
No power to refrigeration unit
Check power supply and connection. Replace if necessary.
Defective temperature sensor Replace temperature sensor.
Defective relay
Replace the heater relay.
Defective control board
Replace the control board
Refrigeration unit
will not run even at
the specifi c cabinet
temperature
No power to refrigeration unit
Check power supply and connection. Replace if necessary.
Defective temperature sensor Replace temperature sensor.
Defective control board
Replace the control board
Unit will only run
in the heater
test mode.
(Located under
tEST)
Defective door switch.
Open and close the door to make sure lights and fan come on. If not, then
check the door switch.
Defective temperature sensor Follow the same steps detailed above about the temperature sensor.
Defective control board
Replace the control board.
Summary of Contents for V21
Page 2: ...I Part 1169256 09 2008 CHAMELEON TABLE OF CONTENTS...
Page 5: ...S 1 Part 1169256 09 2008 CHAMELEON SAFETY SECTION...
Page 8: ...S 4 Part 1169256 09 2008...
Page 20: ...S 16 Part 1169256 09 2008 NOTES...
Page 21: ...G 1 Part 1169256 09 2008 CHAMELEON GENERAL INFORMATION...
Page 29: ...G 9 Part 1169256 09 2008 FIGURE 7...
Page 31: ...G 11 Part 1169256 09 2008 FIGURE 9...
Page 32: ...G 12 Part 1169256 09 2008 NOTES...
Page 33: ...P 1 Part 1169256 ECN 52202 08 2010 CHAMELEON VEC 12 4 Programming Section...
Page 43: ...P 11 Part 1169256 08 2010 Return Exits the programming mode and returns the vendor to stand by...
Page 45: ...P 13 Part 1169256 08 2010...
Page 46: ...C 1 Part 1169256 09 2008 CHAMELEON CABINET PARTS...
Page 48: ...C 3 Part 1169256 09 2008 Purposely left blank...
Page 49: ...C 4 Part 1169256 09 2008 HARDWARE LIST...
Page 50: ...C 5 Part 1169256 09 2008...
Page 51: ...C 6 Part 1169256 09 2008...
Page 53: ...C 8 Part 1169256 09 2008...
Page 55: ...C 10 Part 1169256 09 2008...
Page 57: ...C 12 Part 1169256 09 2008...
Page 59: ...C 14 Part 1169256 09 2008...
Page 62: ...C 17 Part 1169256 09 2008 NOTES...
Page 63: ...TD 1 Part 1169256 09 2008 CHAMELEON Door Parts...
Page 69: ...TD 7 Part 1169256 09 2008...
Page 71: ...TD 9 Part 1169256 09 2008 NOTES...
Page 72: ...M 1 Part 1169256 09 2008 CHAMELEON MAINTENANCE...
Page 79: ...M 8 Part 1169256 09 2008 FIGURE 2...
Page 81: ...M 10 Part 1169256 09 2008 NOTES...
Page 82: ...T 1 Part 1169256 09 2008 CHAMELEON TROUBLESHOOTING...