T-6
Part #1169256
09/2008
Error
DESCRIPTION OF ERROR
CODE
CHECKING METHOD
Corrective Action
Dollar Bill Validator
bC
Bill validator communications - No
bill validator communication for 5
seconds.
If changer or card reader is being
used, check for “CC” or “rC” errors.
If there are no “CC” or “rC” errors:
1) Check bill validator harness; 2)
Replace bill validator. If there is a
“C” or “rC” error: 1) Check control
board MDB harness.
Turn off door switch and wait at least
fi ve seconds. Turn on door switch.
bFUL
Bill validator full - reported by
validator (STACKER command).
Insure bill cashbox is empty and that
the cashbox is properly closed and
in place.
If cashbox appears to be OK,
replace bill validator.
biLL
Bill validator motor is reported as
defective by validator.
No test available.
Replace bill validator.
bJ
Bill jammed -- reported by
validator.
Check bill validator for obstructions
or dirt.
If no obstructions are apparent,
replace bill validator.
brCH
Bill validator check sum is
incorrect.
Turn power switch off. Wait at least
fi ve seconds. Turn power switch on.
Manually clear the error.
If error does not clear, replace bill
validator.
bOPn
Bill validator is open.
Check that bill cashbox is closed and
in correct position.
If cashbox appears to be OK,
replace bill validator.
bS
Bill validator sensor is not
functioning.
Check bill validator for obstructions
or dirt.
If no obstructions are apparent,
replace bill validator.
Card Reader
CrC
There is no card reader
communication for 5 seconds.
If card reader/bill acceptor is being
used, check for “rC’ or “bC” errors.
If there is no “rC” or “bC” error:
1) Check changer harness. 2)
Replace changer.
Turn power switch off. Wait at least
fi ve seconds. Turn power switch on.
If there is a “rC” or “bC” error:
3) Check control board MDB
harness.
CrXY
Most recent “non-transient error”
from the card reader.
No test available.
Refer to card reader manual for
corrective action.
Refrigeration
SENs
The temperature sensor is
defective or unplugged.
Check to see that temperature sensor
harness is plugged into door harness
at air dam area.
If the sensor is unplugged, replug
it.
Check for temperature sensor
connection J7 on control board is
plugged in.
CnPr
System has failed to decrease
temperature 1° per hour while the
compressor is running.
Access relay mode (refer to
programming manual).
Refer to the refrigeration section
on the following pages.
Check refrigeration settings (refer to
refrigeration section of programming
manual).
Change settings as required.
Htr
Heater system has failed to
increase temperature 1° per hour
while heater is on.
Heater circuit not properly wired.
Check electrical connections.
Bad sensor on heater circuit.
Replace sensor.
Defective heating element.
Replace heating element.
Miscellaneous Problems
ds
Door has been open for more than
one hour.
Check the vendor’s door switch to
see if it’s sticking or miswired.
Replace the door switch, if
defective.
Ran
Ram check sum for service mode
settings stored in non-volatile
memory has been corrupted.
No test available.
If error shows up frequently,
replace the control board.
ACLO
AC voltage to the controller is low
for more than 30 seconds.
Check for low voltage at the wall
outlet at unit start-up.
Contact a qualifi ed electrician.
Summary of Contents for V21
Page 2: ...I Part 1169256 09 2008 CHAMELEON TABLE OF CONTENTS...
Page 5: ...S 1 Part 1169256 09 2008 CHAMELEON SAFETY SECTION...
Page 8: ...S 4 Part 1169256 09 2008...
Page 20: ...S 16 Part 1169256 09 2008 NOTES...
Page 21: ...G 1 Part 1169256 09 2008 CHAMELEON GENERAL INFORMATION...
Page 29: ...G 9 Part 1169256 09 2008 FIGURE 7...
Page 31: ...G 11 Part 1169256 09 2008 FIGURE 9...
Page 32: ...G 12 Part 1169256 09 2008 NOTES...
Page 33: ...P 1 Part 1169256 ECN 52202 08 2010 CHAMELEON VEC 12 4 Programming Section...
Page 43: ...P 11 Part 1169256 08 2010 Return Exits the programming mode and returns the vendor to stand by...
Page 45: ...P 13 Part 1169256 08 2010...
Page 46: ...C 1 Part 1169256 09 2008 CHAMELEON CABINET PARTS...
Page 48: ...C 3 Part 1169256 09 2008 Purposely left blank...
Page 49: ...C 4 Part 1169256 09 2008 HARDWARE LIST...
Page 50: ...C 5 Part 1169256 09 2008...
Page 51: ...C 6 Part 1169256 09 2008...
Page 53: ...C 8 Part 1169256 09 2008...
Page 55: ...C 10 Part 1169256 09 2008...
Page 57: ...C 12 Part 1169256 09 2008...
Page 59: ...C 14 Part 1169256 09 2008...
Page 62: ...C 17 Part 1169256 09 2008 NOTES...
Page 63: ...TD 1 Part 1169256 09 2008 CHAMELEON Door Parts...
Page 69: ...TD 7 Part 1169256 09 2008...
Page 71: ...TD 9 Part 1169256 09 2008 NOTES...
Page 72: ...M 1 Part 1169256 09 2008 CHAMELEON MAINTENANCE...
Page 79: ...M 8 Part 1169256 09 2008 FIGURE 2...
Page 81: ...M 10 Part 1169256 09 2008 NOTES...
Page 82: ...T 1 Part 1169256 09 2008 CHAMELEON TROUBLESHOOTING...