14
SM VI, 3157, 3158, 3159, P/N 4211051
Error Codes
CODE DISPLAYS
ERROR DETAIL
1
1
1
1
Too little motor current (under 20mA)
2
2
2
2
Too much time to complete vend (12 Seconds)
3
3
3
3
Coin Mechanism communication error
4
4
4
4
NOVRAM checksum error
5
5
5
5
Health and safety error on temperature sensor 1
6
6
6
6
Health and safety error on temperature sensor 2
7
7
7
7
Bill Validator communication error
8
8
8
8
Card Reader communication error
MOTOR MODE
Motor mode is used to display the number of working motors or to configure the
vendor to the currently working motors.
Press ( B ) to enter motors mode.
M O T O R S
M O T O R S
M O T O R S
M O T O R S
will be displayed.
Press ( A ) or ( C ) to scroll through the Motor Mode sub-menu.
Motors ........................... Motor Count of working motors
Configure....................... Configure vendor to working motors
Press ( B ) again to display the number of working motors.
Press ( E ) to return to the
M O T O R S
M O T O R S
M O T O R S
M O T O R S
display.
Press ( C ) to enter configuration mode.
C O N F I G
C O N F I G
C O N F I G
C O N F I G
will be displayed.
Press ( B ) to automatically configure machine to the currently working motors. After
a short pause
C O N F i g u r e D
C O N F i g u r e D
C O N F i g u r e D
C O N F i g u r e D
will be displayed.
Press ( E ) to exit back to
C O N F I G
C O N F I G
C O N F I G
C O N F I G
.
Press ( E ) again to return to
M O T O R
M O T O R
M O T O R
M O T O R
.
From there press ( C ) to move to Account mode.
A c c o u n t
A c c o u n t
A c c o u n t
A c c o u n t
will display.
NOTE
Summary of Contents for SM VI 3157
Page 1: ...SEPTEMBER 2000 P N 4211051 Rev B Model 3157 3158 3159 Service Manual SNACK FOOD VENDOR SM VI...
Page 14: ...12 SM VI 3157 3158 3159 P N 4211051 A10687 A10688...
Page 44: ...42 SM VI 3157 3158 3159 P N 4211051 SCHEMATIC...
Page 45: ...SM VI 3157 3158 3159 P N 4211051 43...
Page 46: ...44 SM VI 3157 3158 3159 P N 4211051 KEYPAD OVERLAY...