HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-43
© VEMAG 2013
6.6.4.32 End of stick
Display:
End of stick
Selection:
Stop / filled portions / empty casing
Unit:
Number / Millimeter [mm]
Resolution:
1 / 1 mm
Setting range:
0 – 10 (default = 0)
Application:
AH 204, AH 212
• Enter the number of sausages or empty casings that are to be used to
create a gap between two sections (sticks).
• Press
Enter
.
Selecting "Stop" makes this parameter into the stop counter.
If “Filled portions” has been selected, you must specify the number of
portions to hang between the last hook of the previous stick and the first
hook of the next stick.
If “Empty casing” has been selected, you must specify the length in milli-
metres of the empty casing to hang between the last hook of the previous
stick and the first hook of the next stick. For LPG and synchronizing FSL,
only a multiple of the sausage length can be entered. Where the FSL
runs continuously, values can be entered freely. The first portion after the
empty casing is corrected using the “Stick restart” parameter.
In addition, a stop counter can be defined for “Filled portions” and “Empty
casing”, so that a stop is possible irrespective of the “Sausages per stick”
parameter.
The parameter is only displayed if “Hooks per stick” has been defined.
6.6.4.33 Stick restart
Display:
Stick restart
Unit:
Gramme [g]
Resolution:
0,1 g
Setting range:
0,0 – 200,0
Application:
AH 204, AH 212
• Enter the weight correction for the first portion after the empty casing
• Press
Enter
.
This parameter only appears if an empty casing has been defined for
“End of stick”.
Negative values can also be entered, depending on the weight of the por-
tion.
Summary of Contents for HP10E
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...