![VEMAG HP10E Operating Instructions Manual Download Page 102](http://html1.mh-extra.com/html/vemag/hp10e/hp10e_operating-instructions-manual_4010679102.webp)
HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-64
© VEMAG 2013
6.9 Messages
6.9.1 List of messages
If a message should appear which is not included in the list below, please
note the fault number and contact VEMAG Customer Service.
Number
Message
Cause
Remedy
300
IO modules ready
The IO modules are ready.
-
301
Voltage IO module A4
No voltage at module A4.
Check voltage at module A4.
302
IO module A4
IO module A4 is not present or not
functioning properly.
Check that module A4 is firmly
seated; replace the module if
necessary.
311
Voltage IO module A5
No voltage at module A5.
Check voltage at module A5.
312
IO module A5
IO module A5 is not present or not
functioning properly.
Check that module A5 is firmly
seated; replace the module if
necessary.
320
DIAS communication A1
<-> A3
Communication between A1 (PC)
and module A3 (CIC) is defective.
Check the line and the shielding;
replace the module or the PC if
necessary.
321
CIC module A3
Communication module A3 (CIC)
is not present or not functioning
properly.
Check the module power supply
and the DIAS line.
322
Oil leak detected in feed
system drive
The feed system drive has an oil
leak (Dairy).
Eliminate the oil leak.
350
F5: vacuum pump/eleva-
tor/transformer
Monitoring module F5 has found
overheating at the vacuum pump,
hoist unit or power transformer.
Allow the machine to cool down.
Check the vacuum pump and hoist
motors.
351
Voltage F+24V fuse F4
No voltage at F+24V.
Check voltage F+24V and fuse F4.
353
Unexpected signal X3:2
(F6-S2)
Change of status at digital input
A4 X3:2 (F6-S2) without matching
signal at A4 X6.1 (V+24 V).
Check the wiring from A4 to F6.
354
Unexpected signal X3:2
remote-E
Change of status at digital input
X3:2 (remote-E) from module A5
during production.
Check service page 3. Check the
contacts between the remote con-
trol connector and socket.
355
Unexpected signal X2:4
(F6-S4)
Change of status at digital input
A6 X2:4 (F6-S4) without matching
signal at A4 X6.1 (V+24 V).
Check the wiring at A6 to F6.
360
Oil level vacuum pump
The oil level in the vacuum pump
is too low.
Replenish oil if necessary.
362
Sensor under pressure or
defective!
Zero adjustment of pressure
sensor failed.
Clear the sensor for zero adjustment.
Check the sensor and its wiring;
replace the sensor if necessary.
363
IO module A7
IO module A7 is not present or not
functioning properly.
Check that module A7 is firmly
seated; replace the module if
necessary.
Summary of Contents for HP10E
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...