HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-33
© VEMAG 2013
6.6.4.6 Select pumping system
Display:
Pumping system
Selection:
Rotary vane pump type (e.g. 10-rotor)
Application:
Fillers with rotary vane pump
• Enter rotary vane pump type.
• Press
Enter
.
6.6.4.7 Stop counter
Display:
Stop counter
Unit:
Number
Resolution:
1
Setting range:
1 – 9,999
Application:
Stopping the machine automatically after a set number
of portions
• Enter the number of portions after which the machine is to stop.
• Press
Enter
.
The stop counter is active if a value greater than zero is entered.
The stop counter has two functions.
1. Stopping and resetting the counter as soon as the selected number
of pieces is reached (default).
2. Stopping and resetting the counter if more than 4 seconds have
passed since the machine was stopped using the knee lever. To execute
this function, use the
Enter
key to put a tick in the "Auto reset" field.
6.6.4.8 Soft start-up
Display:
Soft start-up
Selection:
Off / On / All portions / First portion / LPG / Ramp adjust-
ment
Unit:
Milliseconds [ms]
Resolution:
1 ms
Setting range:
Machine-dependent - 9,999 ms
Application:
Starting up the filling process gently
• Enter delay for a softer start-up to the filling process.
• Press
Enter
.
Summary of Contents for 168.1004
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...