HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-71
© VEMAG 2013
Number
Message
Cause
Remedy
850
Perform maintenance!
Indication that servicing is required
on the machine.
Perform servicing in accordance
with the operating instructions.
851
Maintenance acknowl-
edged by user
Maintenance reminder confirmed
by user.
-
900
Drives ready
Drives are ready.
-
901
Main drive not found
Main drive not found on CAN bus.
Check power supply at drive con-
troller FU1 and that the CAN bus
lines are correctly wired.
902
Twist drive not found
Linking drive not found on CAN bus. Check power supply at drive con-
troller FU3 and that the CAN bus
lines are correctly wired.
903
Infeed drive not found
Feed unit drive not found on CAN
bus.
Check power supply at drive con-
troller FU2 and that the CAN bus
lines are correctly wired.
907
Communication main drive CAN bus communication with
main drive interrupted.
Check that CAN bus line is wired
correctly.
908
Communication twist drive CAN bus communication with link-
ing drive interrupted.
Check that CAN bus line is wired
correctly.
909
Communication infeed
drive
CAN bus communication with feed
unit drive interrupted.
Check that CAN bus line is wired
correctly.
911
Unexpected twist drive
Unconfigured linking drive found
on CAN bus.
Activate the linking drive in the PC
if necessary.
912
Unexpected infeed drive
Unconfigured feed unit drive found
on CAN bus.
Activate the feed unit drive in the
PC if necessary.
913
Back suction blocked at
PC
Faulty configuration, back suction
lock is active only on PC.
If block required, put the jumper
on the drive controller, otherwise
remove the tick for the block in the
PC.
914
Back suction blocked at
drive
Faulty configuration, back suction
block is active only on the drive.
If block required, put a tick in the
PC, otherwise remove the jumper
on the drive controller.
915
Main drive: timeout can-
celled
There was no stop signal sent
from the main drive to the machine
controller.
Make a note of the error messa-
ges displayed before this error
and inform the VEMAG Customer
Service team.
916
Main drive inhibit
Controller for main drive not
released.
Check controller release at FU1,
terminal 31.
917
Twist drive inhibit
Controller for linking drive not
released.
Check controller release at FU3,
terminal 31.
918
Infeed drive inhibit
Controller for feed unit drive not
released.
Check controller release at FU2,
terminal 31.
919
Main drive application
Fault in the application module.
This fault occurs in combination
with other fault numbers.
Note the numbers of all current
faults and contact VEMAG Serv-
ice.
Summary of Contents for 168.1004
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...
Page 100: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 62 VEMAG 2013...