HP10E / HP12E / HP15E / HP20E - Dairy design
6. Graphical control
6-73
© VEMAG 2013
Number
Message
Cause
Remedy
947
External drive 1 timeout
The reference movement of the
first drive of attachment 2 took too
long.
Check the reference sensor and
the application module. If there is
no error, contact VEMAG Custo-
mer Service.
950
External drives ready
The external drive(s) are ready.
--
952
External drive 1 not found External drive 1 could not be found
on the CAN bus.
Check power supply at drive con-
troller FU1 and that the CAN bus
lines are correctly wired.
953
External drive 1 commu-
nication
CAN bus communication to exter-
nal drive 1 was interrupted.
Check that CAN bus line is wired
correctly.
954
No release for external
drive 1
There is no controller release for
external drive 1.
Check controller release to FU1,
terminal 31.
955
External drive 1 applica-
tion error
Fault in the application module.
This fault occurs in combination
with other fault numbers.
Make a note of the numbers of all
errors displayed before this error
and inform the VEMAG Customer
Service team.
956
External drive 1 manual
External drive 1 is operated by
hand.
Release manual drive button S10.
957
External drive 1 timeout
The reference movement of the
machine‘s external drive 1 took too
long.
Check the reference sensor and
the blade drive‘s application
module. Make a note of the error
number and inform the VEMAG
Customer Service team.
1000 - 2999 Main drive
The main drive controller is report-
ing a fault.
Note the fault number and contact
VEMAG Customer Service.
3000 - 4999 Twist drive
The linking drive controller is
reporting a fault.
Note the fault number and contact
VEMAG Customer Service.
5000 - 6999 Infeed drive
The feed unit drive controller is
reporting a fault.
Note the fault number and contact
VEMAG Customer Service.
7000 - 8999 Belt drive
The belt drive controller is report-
ing a fault.
Note the fault number and contact
VEMAG Service.
21000 -
49999
External drive of attach-
ment 1
There is an error in the external
drive controller.
Note the fault number and contact
VEMAG Customer Service.
20000
Attachment 1 ready
Attachment 2 is ready (e.g. LPG,
FSL).
-
20001
Safety chain open
-
-
20002
No external release signal External release signal not present -
20003
Voltage F+24 V fuse F4
Fuse F4 is defective
-
20004
Unexpected linking head
movement
Spindle drive moves the linking
head in the casing brake even
though two-handed operation has
not been activated
-
20005
Linking head return si-
gnals faulty
Spindle drive encoder return not
working
-
Summary of Contents for 168.1004
Page 8: ......
Page 10: ...HP10E HP12E HP15E HP20E Dairy design 0 Foreword 0 2 VEMAG 2013...
Page 26: ...HP10E HP12E HP15E HP20E Dairy design 3 Installation and commissioning 3 6 VEMAG 2013...
Page 34: ...HP10E HP12E HP15E HP20E Dairy design 4 Setting up 4 8 VEMAG 2013...
Page 38: ...HP10E HP12E HP15E HP20E Dairy design 5 Operation 5 4 VEMAG 2013...
Page 52: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 14 VEMAG 2013 Mode group Mode View...
Page 56: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 18 VEMAG 2013...
Page 58: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 20 VEMAG 2013...
Page 60: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 22 VEMAG 2013...
Page 97: ...HP10E HP12E HP15E HP20E Dairy design 6 Graphical control 6 59 VEMAG 2013...