VTSSD4
V. 01
–
15/05/2014
6
©Velleman nv
hot air function
17
UP button (
▲
) to increase temperature
21
SET button
18
DOWN button (
▼
) to decrease temperature
22
UP button (
▲
) to increase airflow
19
temperature display
23
airflow display
20
heating indication
24
DOWN button (
▼
) to decrease airflow
7.
Installation
7.1
Installing the Fume Extractor
This device comes with a fume extractor. Use this extractor always when soldering or desoldering.
To install the fume extractor, proceed as follows:
1.
Make sure that there is a filter in the device (see
Replacing Filters
).
2.
Place the extractor near the working area.
3.
Plug the power cord into the back of the fume extractor, and plug the other end into a suitable main outlet.
4.
Switch the extractor on.
7.2
Installing the Rework Station
Make sure that the operating voltage of the unit is identical to that of the electrical supply.
In order to protect the pump during transportation, the pump in the machine is fixed by 4 screws in
the base plate. You must unscrew the pump first; otherwise, you may damage the device
permanently.
Always place the irons and the hot air gun in their holders, even if the device is switched off or not
in use. Do not place them on the table or any other surface.
To install the rework station, proceed as follows:
1.
Before the first use, remove the 4 screws in the base plate that protect the pump. Refer to the illustration
below:
2.
Place the device on a level, stable, and fire resistant working surface.
3.
Screw the holder to the station. You can fit the holder on the left or right side:
4.
Plug the soldering iron into the soldering iron connection
[2]
and place the iron in its holder. Note that the
connector has a notch; it only fits in one way. Do not force.
5.
Plug the desoldering iron into the desoldering iron connection
[4]
, plug the vacuum tube to the VAC
connection
[5]
, and place the iron in its holder. Note that the connector has a notch; it only fits in one way.
Do not force.
6.
Plug the hot air gun into the hot air connection
[6]
, and place the gun in its holder.
7.
Make sure that the power switch
[1]
is in the off position (0).
8.
Plug the power cord into a suitable, earthed mains outlet.