E300GSM
V. 01 – 04/10/2017
2
©Velleman nv
11.
Temperature Control
Connect the included temperature sensor. The temperature will be displayed
in an SMS.
The temperature control function is useful when the power output is
connected to a heating or cooling device. The power will automatically switch
on/off according to temperature changes.
Set control parameters: #24#0#mode#low-temp#high-temp#
Mode parameters: 1 (warming) or 2 (cooling).
Temperature range: -30 °C to 100 °C.
Example: #24#0#1#15#25# means power on when
temperature < 15 °C, power off when temperature > 25 °C.
Activate temperature control function: #23#0#1#
Manually switch on/off the device to abort this function automatically.
12.
Temperature Alarm
Connect the included temperature sensor. You will be notified by SMS when
the temperature is out of range.
Set alarm range: #22#0#low-temp#high-temp#
Temperature range: -30 °C to 100 °C.
Activate temperature alarm: #21#0#1#
Deactivate temperature alarm: #21#0#0#
13.
Wired Sensor Alarm
The power control accepts two wired sensor inputs, one constant 12 VDC
output and one controllable 12 VDC output. The constant 12 VDC output can
act as a power supply for the wired sensors. The input sensors are of the
NO/NC type. Connect the wired sensors and COM PIN to the S1 and S2
terminals. Do not connect S1 and S2 to the power supply as this can
irreversibly damage the device.
The power control will send an SMS when the sensor is triggered.
SMS when sensor alarm on: #40#1#
SMS when sensor alarm off: #40#0#
Change sensor name: #43#sensor-1#sensor-2#
Example: #43#door#window# means door = sensor 1,
window = sensor 2. The respective name will appear in the SMS.
Change alarm mode: #44#sensor-number#mode#
Sensor number: 1 or 2. Mode: 1, 2 or 3. Mode 1: NC (only alarm when
two terminals are open), mode 2: NO (only alarm when two terminals
are closed), mode 3: NO/NC (only alarm when two terminals are open
or closed).
14.
Auto Control When Triggered
Use this function as a smart control for your home, e.g. as motion detector.
Sensor trigger, auto turn on 230 V power: #42#220#time#
Time range: 1-1800, i.e. turn on power for 1-1800 seconds. Function
turn off at set time 0 (default value).
Sensor trigger, auto turn on 12 VDC power: #42#12#time#
Time range: 1-1800, i.e. turn on power for 1-1800 seconds. Function
turn off at set time 0 (default value = 60).
A triggered sensor can switch on 230 V and 12 VDC according to the settings.
15.
Advanced Settings
SMS when on/off button pressed
Default send SMS when M button is pressed.
SMS when on-off button pressed on: #03#1#
SMS when on-off button pressed off: #03#0#
SMS when power lost or restore
Default send SMS when main power supply is lost or restored.
SMS when power lost or restored on: #05#1#
SMS when power lost or restored off: #05#0#
SMS when calling operation
Default send SMS when calling.
SMS when calling on: #41#1#
SMS when calling off (default): #41#0#
Reset factory settings
There are two methods to restore the factory settings:
Method 1: The master uses sends an SMS.
Reset factory settings: #08#1234#
Method 2: Hold the M button pressed for ten seconds. The factory settings
are re-loaded after the beep.
16.
SMS Command List
category
function
command
Define users
Register master number
#00#
Add family number
#06#family-number#
Check family number
#06#
Delete family number
#15#family-number#
Delete all family numbers
#15##
Power control
Set calling to switch power
#09#1#
Set calling to switch on
power for some seconds
#09#2#time#
Switch off calling function
#09#2#
Power on
#01#0#
Power off
#02#0#
Delay control
Turn off power for some
minutes
#12#0#minutes#1#
Turn on power for some
minutes
#12#0#minutes#0#
Schedule control
Schedule control on
#19#0#1#
Set schedule control
parameters
#20#0#workday#
starttime#endtime#
Temp control
Temp control on
#23#0#1#
Set temp control parameters
#24#0#mode#
low-temp#high-temp#
warming=1, cooling=2
Temp alarm
Temp alarm on
#23#0#1#
Set temp range
#22#0#mintemp#maxtemp#
Temp alarm off (default)
#21#0#1#
Sensor alarm
Sensor alarm on
#40#1#
Sensor alarm off
#40#0#
Change sensor name
#43#sensor1#sensor2#
Change alarm mode
#44#sensor-number#mode#
Sensor trigger, turn
on power
Sensor trigger, auto turn on
230 V power
#42#220#time#
Sensor trigger, auto turn on
12 VDC power
#42#12#time#
SMS notifications
SMS when on-off button
pressed on (default)
#03#1#
SMS when on-off button
pressed off
#03#0#
SMS when power lost or
restore on (default)
#05#1#
SMS when power lost or
restore off
#05#0#
SMS when calling on
#41#1#
SMS when calling off (default)
#41#0#
SMS to users on (default)
#16#1#
SMS to users off
#16#0#
Check status
Check status
#07#
Check delay control status
#34#
Check schedule control
status
#33#
Check temp control status
#32#
Check temp alarm status
#35#
Check GSM signal
#27#
GSM signal alert on
#27#1#
GSM signal alert off (default)
#27#0#
Reset
Reset factory setting
#08#1234#
17.
Cleaning and Maintenance
Occasionally wipe with a damp cloth occasionally to keep it looking new. Do
not use harsh chemicals, cleaning solvents or strong detergents.
18.
Technical Specifications
1 channel
max. power loading .............................. 3500 W, 16 A (two lines control)
power input ........................................................ 110-230 V~, 50/60 Hz
power output ................... 110-230 V~, 50/60 Hz, 12 VDC (max. 200 mA)
GSM frequency ............................................... 850/900/1800/1900 MHz
SIM card slot ......................................................standard size SIM card
wired sensor input ..................... NO (normal closed) or NC (normal open)
wired sensor cable length ................................................ 2 m (included)
GSM antenna .......................................................................... included
dimensions .............................. 90 x 70 x 73 mm (GSM antenna not incl.)
weight .......................................................................................222 g
max. users ......................................................... 5 (1 master / 4 users)
Use this device with original accessories only. Velleman nv cannot be
held responsible in the event of damage or injury resulting from
(incorrect) use of this device. For more info concerning this product
and the latest version of this manual, please visit our website
www.perel.eu. The information in this manual is subject to change
without prior notice.