n
Visual inspection for damage
n
Function check: The main contactor pulls in when the green
rocker switch is set to the “ON” position, and drops out when
the green rocker switch is set to the “OFF” position.
CAUTION!
Electrically skilled person
This check must only be carried out by an electri-
cally skilled person.
3.4.2 Warning label
Fig. 7: Warning label for blow-down
1
Fill the blow-down tank with cold water (<15°C) until reaching
the mark!
2
Screw the screw cap tightly onto the tank!
3
Slowly and completely open the blow-down ball valve!
The warning label is located on the the back of the machine.
Incorrect blow-down poses a risk of scalding / risk of burns.
Chapter 8.2 ‘Blow-down’ on page 42
instructions.
Main contactor (Pos. 4)
Warning label for blow-down
Safety
Built-in safety devices > Warning label
30.09.2022
Steam generator VEIT SG67
22