Emergency
14.02.11
BRI-7570_020
55
10. EMERGENCY
In case of danger, an emergency shut-down must be carried
out.
In case of emergency:
-
activate the safety frame at the heating plate,
or
-
switch off main switch on the switch cabinet.
The following procedure is triggered:
-
the heating plate opens,
-
the heating is switched off.
In case of a
fire
, switch off the machine and all supply lines
(power, compressed-air, water).
Before operating the machine
-
find out where the fire extinguisher is located,
-
learn how to handle the fire extinguisher,
-
inform yourself on how to report fires without delay.
A risk of fire may be caused by inflammable liquids and mix-
tures of liquids and gases (e.g. oil oxygen mixture).
Fire extinguishers to be used in accordance with fire classifica-
tion DIN EN 2:
-
powder fire extinguisher for class A, B, C fires designed for
solid, liquid and gaseous substances,
-
powder fire extinguishers for class D fires designed for in-
flammable metal,
-
carbon dioxide fire extinguishers for liquid, gaseous and
solid substances.