QUICK OPERATING KEYS
[VICON PROTOCOL]
If user wants to choose Vicon Protocol, the user may change the dip switch first.
(Refer to Page #36 DIP SWITCH SETTING - PROTOCOL) Baud Rate: 4800 (Vicon
default)
The operation system is almost same as Pelco D/P protocols but some special features are
different way as noted below’
<Quick Operation Key Table 2: VICON>
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Website:
www.Veilux.net
Phone # 1-800-510-6528
Number
Note
Function
1 ~ 79 +Preset
PRESET
Execute Preset 1 ~ 79
80~87 +Preset
GROUP TOUR
Execute Group Tour #1 ~ #8
88~89 +Preset
PATTERN
Execute Pattern #1 ~ #2
90 + Preset
Focus Mode Set
Focus Mode Toggle to Auto or Manual
90 + Preset Save
Pan/Tilt Lockout
PAN/TILT Lock or Unlock setting
91 + Preset Save
ZERO POSITION
Search For Pan / Tilt Zero Position
92 + Preset Save
ALARM
Selectable Enable/Disable all Alarms
93 + Preset Save
BLC MODE
Selectable On/Off in BLC function
94 + Preset Save
OSD MAIN MENU
To enter OSD Main Menu
95 + Preset Save
D/N MODE
Selectable Day/Night Mode (Auto/Day/Night Mode)
96 + Preset Save
SECTOR
SECTOR setting menu entrance
97 + Preset Save
DOME Reset
Initial DOME Reset - Rebooting
98 + Preset Save
AUTO PAN
AUTO PAN setting menu entrance
99 + Preset Save
Pan/Tilt Speed
Manual Pan/Tilt Max Speed setting
Menu
Function
Tilt Up / Down
Sub menu cursor moves up / down
Pan Left / Right
Enter to the sub menu or status change or decrement
A/P
Using for Enter key when user select YES or NO
A/I
Using for function changing keys when set coordinate
Zoom Tele
Status cursor to the right
Zoom Wide
Status cursor to the left