34
ALARM SET
ALARM NO : 01
ALARM INPUT : OFF
ALARM ACT : 001
SAVE
EXIT
The default setting is OFF.
Veilux Model # VP-58CND12X User Manual
OSD MENU SETTING
I. ALARM SET
4 Alarm inputs are available and each input can activate presets, group tours or patterns.
DEFAULT SETTING
I-1. ALARM SET - ALARM NO.
Up to 4 alarms are selectable by using joystick right or pressing the pan right key when the
cursor is on ALARM NO.
I-2. ALARM SET - ALARM INPUT
Alarm inputs can be programmed as NC (Normally Close) or NO (Normally Open)
I-3. ALARM SET - ALARM ACT
Active alarms can trigger modes such as presets, Group tours 1-8, and Patterns 1-8.
Use the joystick or pan keys to select any preset number, group tour no. or pattern no.
I-4. ALARM SET - SAVE
After setting up the alarm features, to save the data move the joystick right or press the pan
right key when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2
automatically to prepare for the next alarm.
I-5. ALARM SET - EXIT
To escape this page, move the joystick right or press the pan right key.
Website:
www.Veilux.net
Phone # 1-800-510-6528
* Before activating Alarms, you must set ALARM ENABLE at DOME SET – ALARM – EN-
ABLE
(Refer to page
23)