36
13 Supplement
VEGAPULS Air 23 • Autarkic device with measured value transmission via radio technology
64314-EN-230606
Cell capacitiance, each
3.6 Ah
Energy content, each
12.96 Wh
Lithium content, each
approx. 0.9 g
Weight, per typ.
23 g
Self-discharge
< 1 % after 1 year at 20 °C
Running time - The running time depends on many factors: Ambient tempera-
ture, measuring intervals, network provider, connection quality, …, further de-
tails on the running time are provided by the calculation tool on our homepage:
www.vega.com/en-de/products/product-catalog/level/radar/vegapuls-air-runtime-calculation
Interval
LoRaWAN
NB-IoT/LTE-M
15 minutes
ø 1.59 years
ø 54 days
8)
30 minutes
ø 2.9 years
ø 107 days
9)
1 h
ø 4.96 years
ø 210 days
10)
2 h
ø 7.69 years
ø 1.11 years
3 h
ø 9.43 years
ø 1.62 years
4 h
> 10 years
ø 2.09 years
6 h
11)
ø 2.95 years
8 h
ø 3.72 years
12 h
ø 5.02 years
24 h
ø 7.75 years
Additional output parameter - Electronics temperature
Range
-20 … +60 °C (-4 … +140 °F)
Resolution
< 0.1 K
Deviation
±3 K
Electrical protective measures
Protection rating
Ʋ
Glued connection
IP66/IP69 acc. to IEC 60529, Type 6P acc. to NEMA
12)
Ʋ
Flexible exchangeable bracket, ceiling
mounting
IP66/IP68 (IPX8: 0.2 bar for 24 hr) acc. to IEC 60529,
Type 6P acc. to NEMA
Ʋ
Vessel mounting with ceiling bracket IP66/IP68 (0.2 bar) acc. to IEC 60529, type 6P acc. to
NEMA
Altitude above sea level
2000 m (6562 ft)
Protection class
None (autarcic operation)
Pollution degree
4
8)
Small measuring intervals with NB-IoT/LTE-M preferably for test measurements
9)
Small measuring intervals with NB-IoT/LTE-M preferably for test measurements
10)
Small measuring intervals with NB-IoT/LTE-M preferably for test measurements
11)
Factory default setting
12)
Specifications apply to housings. With IP69 for adhesive bonding in addition to the adhesive tape 2-component
adhesive, e.g. 3M type 8005, is additionally required