39
13 Supplement
VEGAPULS Air 23 • Autarkic device with measured value transmission via radio technology
64314-EN-230606
OK
Error 1 Error 2 GPS
Info1
Info2
Info3
Info4
Packet
18
19
20
21
23
24
25
26
Number of bytes
Manufacturer code
4
Device Type
4
Software version System
1
Software version Function
1
Software version Error
1
Software version Customer
1
Measurement/transmission interval
7
Change counter
2
Scaling min.
4
Scaling max.
4
Device Name
Device Tag
Total
11
9
9
10
11
10
11
10
NAMUR status
NAMUR status
Message NAMUR status
0
1
2
3
4
Meaning
Good
Function
Check
Maintenance
request
Out of speci-
fication
Failure
VEGA Device status
VEGA Device status
Message VEGA device status
1016 …
… 32100
Meaning
see "
Message detail status
" in chapter "
Status mes-
sages acc. to NAMUR NE 107
"
Example data transmission
Packet 8, data record 0x083FA31F152D242009
Byte 1
Byte 2 … 5
Byte 6
Byte 7
Byte 8 … 9
Byte 10
Byte 11
0x08
0x3FA31F15
0x2D
0x24
0x0104
0x20
0x09
Packet iden-
tifier
Measured
value
Unit measured
value
Remaining ca-
pacity of the
battery in %
Temperature
Unit temper-
ature
Angle of incli-
nation to the
perpendicular
8
1.27439
0x2D = 45 = m 36 %
26
0x20 = 32
= °C
9°