Vega VEGABAR 53 Operating Instructions Manual Download Page 7

3

P

roduct description

3

.

1

C

on

guration

T

he scope of delivery encompasses

:

l

VEGABAR

53

process pressure transmitter

l

D

ocumentation

-

this operating instructions manual

-

test certi

cate

-

E

x

-

speci

c safety instructions

(

with

E

x versions

)

and

,

if

necessary

,

further certi

cates

-

O

perating instructions manual

"

I

ndicating and adjust

-

ment module

PLICSCOM

"

-

optional

-

S

upplementary instructions manual

"

P

lug connector for

continuously measuring sensors

"

-

optional

VEGABAR

53

consists of the following components

:

l

P

rocess

tting with measuring cell

l

H

ousing with electronics

,

optionally available with plug

connector

l

H

ousing cover

,

optionally available with indicating and

adjustment module

PLICSCOM

T

he components are available in di

erent versions

.

1

2

3

F

ig

.

1

:

E

xample of a

VEGABAR

53

with manometer connection

G

½

A

acc

.

to

EN

837

and plastic housing

1

H

ousing cover with integrated

PLICSCOM

(

optional

)

2

H

ousing with electronics

3

P

rocess

tting with measuring cell

S

cope of delivery

C

omponents

VEGABAR

53

-

P

ro

bus

PA

7

P

roduct description

28250

-

EN

-

051004

Summary of Contents for VEGABAR 53

Page 1: ...Operating Instructions VEGABAR 53 Pro bus PA p...

Page 2: ...ransport 10 4 Mounting 4 1 General instructions 11 4 2 Mounting information 12 4 3 Mounting procedure 12 5 Connecting to power supply 5 1 Preparing the connection 14 5 2 Connection procedure 15 5 3 Wi...

Page 3: ...Supplementary operating instructions manuals Information VEGABAR 53 is available in di erent versions and is supplied order speci cally Depending on the selected version sup plementary operating instr...

Page 4: ...m 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangerous situation that could occur Ignoring this ca...

Page 5: ...tions VEGABAR 53 is a high tech instrument requiring the strict observance of standard regulations and guidelines The user must take note of the safety instructions in this operating instructions manu...

Page 6: ...port as well as Mounting must be noted Furthermore the valid regulations implementation instructions and memorandums of the BG professional assoc must be noted 2 8 Environmental instructions Protectio...

Page 7: ...measuring sensors optional VEGABAR 53 consists of the following components l Process tting with measuring cell l Housing with electronics optionally available with plug connector l Housing cover optio...

Page 8: ...ownloads Software Pro bus There you can also nd the appropriate certi cates In a PDM environment an EDD Electronic Device Description is also required to enable the full range of sensor functions also...

Page 9: ...versions PE foam or PE foil is also used Dispose of the packaging material via specialised recycling companies Instruments for oxygen applications are welded in PE foil and provided with a label Oxyge...

Page 10: ...lso install the indicating and adjustment module in four di erent positions each displaced by 90 Use the recommended cable see chapter Connecting to power supply and tighten the cable gland You can gi...

Page 11: ...ents from the line of VEGA mounting accessories l Welded socket G1B front ush max 150 C 302 F article no 2 27868 l Welded socket G1B front ush O ring article no 2 27867 l Welded socket G B article no...

Page 12: ...Warning The housing must not be used to screw the instrument in Applying tightening force to the housing can damage its internal mechanical components 12 VEGABAR 53 Pro bus PA Mounting 28250 EN 051004...

Page 13: ...the cable entry Please make sure that your installation is carried out acc to the Pro bus speci cation In particular make sure that the termination of the bus is done with appropriate terminating resi...

Page 14: ...nd of all capacitors must not exceed 10 nF in Ex applications Take note of the corresponding installation regulations for Ex applications In particular make sure that no potential equal isation curren...

Page 15: ...ground terminal and the external ground terminal to potential equalisation 11 Tighten the compression nut of the cable entry the seal ring must completely encircle the cable 12 Screw the housing cove...

Page 16: ...1 2 Fig 5 Electronics and connection compartment single chamber housing 1 Plug connector for VEGACONNECT I C interface 2 Spring loaded terminals for connection of the external indication VEGADIS 61 3...

Page 17: ...ig 7 Double chamber housing 1 Housing cover connection compartment 2 Blind stopper or plug M12x1 for VEGADIS 61 option 3 Housing cover electronics compartment 4 Filter element for pressure compensatio...

Page 18: ...on compartment 3 Terminals for VEGADIS 61 3 1 2 Display 1 2 I2C Fig 9 Connection compartment double chamber housing 1 Plug connector for VEGACONNECT I C interface 2 Ground terminal for connection of t...

Page 19: ...ies out a self test for approx 30 seconds The following steps are carried out l Internal check of the electronics l Indication of the instrument type the rmware version as well as the sensor TAGs sens...

Page 20: ...justment module PLICSCOM 6 2 Installing the indicating and adjustment module PLICSCOM PLICSCOM can be inserted or removed at any time It is not necessary to interrupt the power supply To mount proceed...

Page 21: ...you intend to retro t VEGABAR 53 with a PLICSCOM for continuous measured value indication a higher cover with an inspection glass is required VEGABAR 53 Pro bus PA 21 Setup with the indicating and adj...

Page 22: ...input jump to the next higher menu The sensor is adjusted via the four keys of the indicating and adjustment module The LC display indicates the individual menu items The functions of the individual...

Page 23: ...g and adjustment module PLICSCOM Process pressure measurement Set up VEGABAR 53 in the following sequence 1 Select the adjustment unit 2 Carry out position correction 3 Carry out zero adjustment 4 Car...

Page 24: ...ment will be displayed Units of measurement bar 3 Activate the selection with OK and select the requested unit with in the example mbar 4 Con rm with OK and move to position correction with The adjust...

Page 25: ...s are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with OK Proceed as follows 1 Edit the mb...

Page 26: ...you switch over from Process pressure to Level measurement In the menu item Units of measurement you select the physical unit in which the adjustment should be carried out e g mbar bar psi The positio...

Page 27: ...with OK To switch over to another adjustment unit in the example from bar to mbar proceed as follows 6 1 Push the OK button in the measured value display the menu overview is displayed Basic adjustme...

Page 28: ...ted unit with in the example m 4 Con rm with OK the submenu Density unit appears Units of measurement Density unit kg dm pcf 5 Select the requested unit e g kg dm with and con rm with OK the submenu D...

Page 29: ...u simply enter the indicated actual measured value If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the disp...

Page 30: ...If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with OK The setup...

Page 31: ...0 0 P 000 mbar 53 mbar 1 5 Span 100 00 P 1000 mbar 53 mbar 1 6 Linearization curve Linear 1 7 Channel PV lin perc 1 8 Damping 1 s 1 9 Sensor TAG Sensor Display 2 Basic adjustment Display Diagnostics S...

Page 32: ...4 Simulation Start simulation 4 5 Reset Reset 4 6 Language Deutsch 4 7 Copy sensor data Copy sensor data 4 8 PIN Enable 4 9 Application Process pressure Info 5 Basic adjustment Display Diagnostics Ser...

Page 33: ...n be read out of the sensor into PLICSCOM The procedure is described in the operating instructions manual Indicating and adjustment module PLICSCOM in the menu item Copy sensor data The data remain th...

Page 34: ...no 2 27323 l Power supply unit 7 2 Parameter adjustment with PACTware Further setup steps are described in the operating instructions manual DTM Collection PACTware attached to each CD and which can...

Page 35: ...rogram PDM are available as EDD The device description are already implemented in the current versions of PDM For older versions of PDM they are available as a free of charge download from the Interne...

Page 36: ...is way and faults can be recti ed Should these measures not be successful please call in urgent cases the VEGA service hotline under the phone number 49 1805 858550 The hotline is available to you 7 d...

Page 37: ...does not appear during connection setup l Pro bus DP cable pole reversed Check the cable and correct if necessary l Incorrect termination Check termination at the beginning and end points of the bus...

Page 38: ...m of a module in the housing If this electronics is defective it can be exchanged by the user The electronics modules di er only in their signal output and are suitable for all VEGABAR series 50 and 6...

Page 39: ...ega com under Services Downloads Forms and Certi cates Repair form By doing this you help us carry out the repair quickly and without having to call back for needed information l Print and ll out one...

Page 40: ...r 9 2 Disposal VEGABAR 53 consists of materials which can be recycled by specialised recycling companies We have purposely de signed the electronic modules to be easily separable Mark the instrument a...

Page 41: ...using plastic PBT Polyester Alu die casting pow der coated 316L 1 4435 Seal ring between housing and housing cover NBR stainless steel housing silicone Alu plastic housing Inspection window in housing...

Page 42: ...kPa 1 5 bar 100 500 kPa 35 bar 3500 kPa 1 0 bar 100 kPa 1 15 bar 100 1 5 MPa 80 bar 8 MPa 1 0 bar 100 kPa Absolute pressure 0 0 4 bar 0 0 kPa 2 bar 20000 kPa 0 1 6 bar 0 160 kPa 10 bar 1 000 kPa 0 6...

Page 43: ...rature coe cient of the zero signal Standard typ 0 2 10 K Meas ranges 0 0 1 and 0 0 16 bar typ 0 4 10 K Average temperature coe cient of the span typ 0 2 10 K Long term stability similar to DIN 16086...

Page 44: ...ture depending on seal and O ring14 Viton 20 105 C 4 221 F EPDM 40 105 C 40 221 F NBR 25 105 C 13 221 F Product temperature with connection G1A front ush acc to EHEDG Viton EPDM NBR 10 150 C 14 302 F...

Page 45: ...M12x1 for VEGADIS 61 option or l 1x closing cap NPT 1x blind stopper NPT plug M12x1 for VEGADIS 61 option or l 1x plug depending on the version 1x blind stopper M20x1 5 plug M12x1 for VEGADIS 61 opti...

Page 46: ...ross section 0 5 mm wire resistance 0 036 Ohm m tensile load 1 200 N 270 pounds force Standard length 5 m 16 4 ft max length 1000 m 3280 ft Min bending radius 25 mm with 25 C 77 F Diameter approx 8 mm...

Page 47: ...on class II Available approvals or approvals applied for18 19 ATEX ia ATEX II 1G 1 2G 2G EEx ia IIC T6 ATEX ia a d ATEX II 1 2G 2G EEx d ia IIC T6 ATEX D ATEX II 1 2D 2D IP6X T IEC IEC Ex ia IIC T6 FM...

Page 48: ...also included in the name of the GSD le For VEGABAR 53 the ID number is 0x076F hex and the GSD le BR__076F GSD As an option to this manufacturer speci c GSD le PNO provides also a general so called p...

Page 49: ...nsor mounting correction Fig 15 VEGABAR 53 Block diagram with AI PA OUT value and additional cyclical value PROFIBUS PA output Target Mode Failure mode Alarms Scaling Source for scaling ti Damping Sen...

Page 50: ...ort one Format byte e g Allen Bradley l Long for Pro bus master only supporting the Identi er Format byte e g Siemens S7 300 400 Examples of telegram con guration In the following you will see how the...

Page 51: ...ta format of the output signal The status byte corresponds to pro le 3 0 Pro bus PA Pro le for Process Control Devices coded The status Measured value OK is coded as 80 hex Bit7 1 Bit6 0 0 The measure...

Page 52: ...on 0x48 uncertain substitute set l Switch on simulation l Failsafe replacement value Failsafe Mode Fsafe value 0x4c uncertain initial value Failsafe replacement value Failsafe Mode Last valid value a...

Page 53: ...by 9 mm 0 35 in 1 Plastic housing 2 Stainless steel housing 3 Aluminium double chamber housing 4 Aluminium housing Housing in protection IP 66 IP 68 1 bar 117mm 4 39 64 116mm 4 9 16 120mm 4 23 32 103m...

Page 54: ...64 3mm 1 8 3mm 1 8 6mm 15 64 18mm 45 64 30mm 1 3 16 NPT NPT 65mm 2 9 16 25mm 63 64 15mm 19 32 20mm 25 32 G1B 68mm 2 43 64 25mm 63 64 10mm 25 64 30mm 1 3 16 GN GE GV GF GC Fig 24 VEGABAR 53 GV G 1 2A m...

Page 55: ...ABAR 53 hygienic tting LA CA 64mm 2 33 64 78mm 3 5 64 82mm 3 15 64 82mm 3 15 64 Fig 25 VEGABAR 53 CA Tri Clamp 2 LA hygienic tting with compression nut VEGABAR 53 Pro bus PA 55 Supplement 28250 EN 051...

Page 56: ...10 4 Certi cate CE declaration of conformity Fig 26 CE declaration of conformity 56 VEGABAR 53 Pro bus PA Supplement 28250 EN 051004...

Page 57: ...Manufacturer declaration Fig 27 Manufacturer declaration VEGABAR 53 Pro bus PA 57 Supplement 28250 EN 051004...

Page 58: ...10 5 Industrial property rights 58 VEGABAR 53 Pro bus PA Supplement 28250 EN 051004...

Page 59: ...VEGABAR 53 Pro bus PA 59 Supplement 28250 EN 051004...

Page 60: ...com www vega com ISO 9001 All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able...

Reviews: