13 Supplement
FIBERTRAC 31 • Profibus PA
43833-EN-170126
Device name
Instrument ID
GSD file name
VEGA
Instrument class in
profile 3.02
VEGA
Profile-specific
SOLITRAC 31
0xCF4
0x9702
VE010CF4.GSD
PA139702.GSD
POINTRAC 31
0xD48
0x9702
VE010D48.GSD
PA139702.GSD
WEIGHTRAC 31
0xCF8
0x9702
VE010CF8.GSD
PA139702.GSD
Cyclical data traffic
The master class 1 (e.g. PLC) cyclically reads out measured values from the sensor during opera
-
tion. The below block diagram below shows which data can be accessed by the PLC.
1
Electronic
Temperature
Count
Rate
Primary
Value
Fig. 28: FIBERTRAC 31: Block diagram with AI FB 1 … AI FB 3 OUT values
TB Transducer Block
FB 1 … FB 3
Function Block
1 Output value, adjustable (depending on instrument type and application - see following list)
•
Process temperature
•
Vapour density
•
Density
•
Volume flow
•
Ground
•
Belt speed
•
Loading
Module of the PA sensors
For the cyclic data traffic, FIBERTRAC 31 provides the following modules: