background image

Vega Light Control Systems 

● Holland, Michigan 49424

 

3.  ELECTRICAL INSTRUCTIONS 

3.1.  Wiring diagram after installation  

 

 

 

4.  RELATED INFORMATION 

4.1.  Maintenance and Cleaning 

 

Periodic cleaning of fixture will ensure operation at maximum optical efficiency 

 

Refer to fixture installation instructions for maintenance and cleaning guidelines 

 

Even though LED Retrofit Kit may continue to light after the specified lifetime has passed, it must be replaced in 
order to maintain appropriate light levels 

4.2.  List of applicable and related Documents 

 

D4 LED Retrofit Kit Product Information Brochure 

5.  Troubleshooting 

Condition 

Possible Reason(s) 

Recommended Action 

AC surge protector 
damaged 

Surge protector unable to protect 
unit 

1. 

Verify AC voltage at both input and output of surge protector. 

2. 

If within warranty period, contact VEGA sales representative for RMA.  

3. 

If out of warranty period, contact VEGA sales representative for 
information to replace surge protector. 

LEDs are dim or not lit 

1. 

DC Cable is unplugged. 

2. 

Power supply has failed 

 
 
 
3. 

LED board is damaged 

 
 

1. 

Connect the DC Cable by plugging together the two Molex connectors 

2. 

To identify failed power supply, use clamp meter (tongs) to measure 
output current.  Replace if below rated current.  Before replacing power 
supply, verify AC voltage through surge protector.  

3. 

If within warranty period, contact VEGA sales representative for RMA.  
If not within warranty period, LED Light Engine should be replaced as it 
is not user serviceable. 

Difficulty experienced 
during mounting 

--- 

Contact VEGA representative for recommended action  

[email protected] 
616-259-0700 

OR visit 

www.vegalightcontrolsystems.com

 

for additional reference designs. 

 
 
 
 

AC POWER SIDE 

120-277 VAC 

LED SIDE 

36 VDC.   

18AWG Wires 

Note:  AC surge protector to power supply is prewired 

Summary of Contents for D4-F

Page 1: ...TION RISQUE D INCENDIE OU DE CHOC ÉLECTRIQUE L INSTALLATION DE CE NÉCESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS TOUTE PERSONNE QUI N EST PAS QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE D INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE RISQUE D INCENDIE OU DE CHOC ÉLECTRIQUE N INSTALLE...

Page 2: ...N FIXTURE AMBIENT OPERATING TEMPERATURE FOR LED RETROFIT MODULE 104 F 40 C MAXIMUM AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140 F 60 C INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE RETROFITTED IF UNCERTAIN CONTACT VEGA LIGHT CONTROL SYSTEMS CUSTOMER SERVICE TO EVALUATE APPLICABILITY TO FIXTURE SUPPORT VEGALIGHTCONTROL COM PHONE 616 259 0700 1 PRODUCT OVERVIEW 1 1 D4 Post Top Ret...

Page 3: ...pplication Specific configuration for mounting in Granville Classic 7 and 4 fitters with 19 glass globes One piece assembly Granville Premier Kit Style Watts CCT Type Mounting Dimming Mounting Code Details D4 H 30 22K T5M CGPCS STD Granville Premier w Photo Control Socket D4 H 40 30K T3M NA CGPNS DIM Granville Premier w o Photo Control Socket D4 H 60 40K H PXYZ H prefix is high output version 80 N...

Page 4: ...0 mm LED Light Engine Height Adjustable From 15 Down To 9 75 D4 F Model Fully Enclosed 60W Max Adapter Plate D4 S Down Light Model with Side Brackets D4 M Model Mid Mount Enclosed 80W Max 4 73 or 5 91 120 or 150 mm Height Adjustable From 11 Down To 9 75 Connected by 24 Cable w Connectors 6 6 167 mm 4 5 115 mm D4 C Model Socket Replacement 4 73 or 5 91 120 or 150 mm 6 6 167 mm 4 5 115 mm Extrusion ...

Page 5: ... LexaLite Lindy 408 globe performs best at LED height set 8 from the base of the globe Crown 88266 CL has an optimum output when set 13 from the base of the globe 5 Measure the maximum temperature achieved at the locations shown below after at least 2 hours under power inside fixture Take that temperature and add the difference between room temperature and 40C to calculate the maximum Tc For examp...

Page 6: ...before servicing WARNING Risk of burn Allow unit to cool fully before servicing POST TOP Note Failure to remove original components including ballast will void product warranty Original optical components reflectors Fixture Dome Top Ballast Socket Lamp Fixture Base Fixture Globe Note Kits are available for specific targeted luminaries Holophane Granville Premier cat No GVP Granville Classic cat No...

Page 7: ...ight tighten set screw enough to hold tube then tighten another turn with hex key see 1 4 2 4 Side brackets can be adjusted bent trimmed or special ordered to span or offset LED mounting height Allow adequate space around all sides of LED Light Engine from fixture or globe see 1 4 5 Order a lower wattage of kit if install is still exceeding Tc limits with LED kit properly positioned Assembled Retr...

Page 8: ...facing the street see 1 4 6 Re use screws previously holding HID ballast to fixture to attach Retrofit Kit when possible Additional hardware maybe required For Post Top fixtures LED Light should be installed to maintain cooling clearance above heatsink and at arc tube height of replaced HID see 1 4 5 Restore the original light fixture sealing for water and insect control Rain water must not enter ...

Page 9: ... Black or Blue using pre installed Lever Nuts If photocell controlled or remote controlled connect Retrofit Kit to output of the control 2 5 STEP 5 Secure fixture components Secure fixture components and restore original light fixture sealing for water and insect control Notes Additional hardware maybe required to mount LED Retrofit Kit in fixture Re use screws previously holding HID ballast to fi...

Page 10: ...arranty period contact VEGA sales representative for RMA 3 If out of warranty period contact VEGA sales representative for information to replace surge protector LEDs are dim or not lit 1 DC Cable is unplugged 2 Power supply has failed 3 LED board is damaged 1 Connect the DC Cable by plugging together the two Molex connectors 2 To identify failed power supply use clamp meter tongs to measure outpu...

Reviews: