background image

Vega Light Control Systems 

● Holland, Michigan 49424

 

1.4.  Fixture Considerations 

1. 

Do not use a Type 3 LED Light Engine in a Refracted Globe. 

Type 3

 

Refracted globes will effectively convert 

the T5M retrofit kit into a Type 3 distribution in globes such as the Lindy Type 3 and the Granville Type 3. 

2. 

Do not mount LED Light Engine too high in the globe.

 The LED Light Engine needs adequate air space 

above it to dissipate heat. Additional air space may be needed for Tc limits as shown below. 

3.  The arc tube height of the previous HID system is typically the proper height for the LED mounting. This is 

especially true for refracted globes to maintain the proper pattern of light to the ground and avoid excessive up 
light.  

4.  Example Globes vs LED height settings:  

 

LexaLite Lindy 424 globe arc tube height is designed at 

11.3” from the base of the globe. 

 

LexaLite 

Lindy 408 globe performs best at LED height set 8” from the base of the globe. 

 

Crown 88266-CL has an optimum output when set 

13” from the base of the globe. 

 

5.  Measure the maximum temperature achieved at the locations shown below after at least 2 hours under power 

inside fixture. Take that temperature and add the difference between room temperature and 40C to calculate 
the maximum Tc.  

  For example: Room is 22C, Tc measured is 62C, the compensated maximum Tc is 80C 

 

 

6. 

When using Type 3 LED Retrofit Kits orient the LED Light Engine as shown below

 

 

 

 

LED Light Engine 

 

Tc Point < 90

Osram Power Supply

 

Measured at marked Tc Point < 85

Remove power supply cover as needed to reach Tc point on power supply 

Meanwell Power Supply

 

Tc Point < 85

Measured at center of label 

When the arc tube 

height is unknown, 

place the LED height at 

the center of the globe. 

This LED surface is 

should be installed at the 

previous arc tube height. 

150mm 80W LED Light Engine 

120mm 30-60W LED Light Engine 

Street Side 

Arrow 

House 

Side 

House 

Side 

Street 

Side 

Street 

Side 

Summary of Contents for D4-C

Page 1: ...SDICTION RISQUE D INCENDIE OU DE CHOC LECTRIQUE L INSTALLATION DE CE N CESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILI RE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYST ME LECTRIQUE DU LUMINAIR...

Page 2: ...FIXTURE AMBIENT OPERATING TEMPERATURE FOR LED RETROFIT MODULE 104 F 40 C MAXIMUM AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140 F 60 C INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE R...

Page 3: ...plication Specific configuration for mounting in Granville Classic 7 and 4 fitters with 19 glass globes One piece assembly Granville Premier Kit Style Watts CCT Type Mounting Dimming Mounting Code Det...

Page 4: ...mm LED Light Engine Height Adjustable From 15 Down To 9 75 D4 F Model Fully Enclosed 60W Max Adapter Plate D4 S Down Light Model with Side Brackets D4 M Model Mid Mount Enclosed 80W Max 4 73 or 5 91...

Page 5: ...LexaLite Lindy 408 globe performs best at LED height set 8 from the base of the globe Crown 88266 CL has an optimum output when set 13 from the base of the globe 5 Measure the maximum temperature achi...

Page 6: ...efore servicing WARNING Risk of burn Allow unit to cool fully before servicing POST TOP Note Failure to remove original components including ballast will void product warranty Original optical compone...

Page 7: ...ght tighten set screw enough to hold tube then tighten another turn with hex key see 1 4 2 4 Side brackets can be adjusted bent trimmed or special ordered to span or offset LED mounting height Allow a...

Page 8: ...acing the street see 1 4 6 Re use screws previously holding HID ballast to fixture to attach Retrofit Kit when possible Additional hardware maybe required For Post Top fixtures LED Light should be ins...

Page 9: ...Black or Blue using pre installed Lever Nuts If photocell controlled or remote controlled connect Retrofit Kit to output of the control 2 5 STEP 5 Secure fixture components Secure fixture components a...

Page 10: ...rranty period contact VEGA sales representative for RMA 3 If out of warranty period contact VEGA sales representative for information to replace surge protector LEDs are dim or not lit 1 DC Cable is u...

Reviews: