background image

Vega Light Control Systems 

● Holland, Michigan 49424

 

NOTICE

 

  TO AVOID ELECTRIC SHOCK, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OR SERVICING. 

  TO PREVENT ELECTRIC SHOCK THIS PRODUCT MUST BE PROPERLY GROUNDED. 

  INSTALLATION MUST BE STRUCTURALLY SOUND TO PREVENT PERSONAL INJURY DUE TO FIXTURE COLLAPSE.   

  USE CAUTION WHEN HANDLING DURING OR AFTER OPERATION AS IT MAY BECOME HOT AND CAUSE BURNS. 

  FAILURE TO INSTALL THIS PRODUCT IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), OR THE CANADIAN 

ELECTRICAL CODE (CSA 22.1), ALL APPLICABLE FEDERAL, STATE AND LOCAL ELECTRIC CODES AS WELL AS THE 
SPECIFIC UNDERWRITERS LABORATORIES (UL) SAFETY STANDARDS FOR THE INSTALLATION, LOCATION AND 
APPLICATION MAY CAUSE UNSAFE SITUATIONS LEADING TO SERIOUS PERSONAL INJURY, DEATH, PROPERTY 
DAMAGE AND/OR PRODUCT MALFUNCTION. 

  THIS  DEVICE  COMPLIES  WITH  PART  15  OF  THE  FCC  RULES.    OPERATION  IS  SUBJECT  TO  THE  FOLLOWING  TWO 

CONDITIONS:  (1)  THIS  DEVICE  MAY  NOT  CAUSE  HARMFUL  INTERFERENCE,  AND  (2)  THIS  DEVICE  MUST  ACCEPT  ANY 
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 

  FAILURE OF FIXTURE TO PROVIDE SUFFICIENT WEATHER PROTECTION VOIDS WARRANTY. 

  TO PREVENT EARLY PRODUCT FAILURE, THIS PRODUCT SHOULD BE INSTALLED IN OPERATING ENVIRONMENTS WITH 

MAXIMUM  MEAN FIXTURE  AMBIENT  OPERATING  TEMPERATURE FOR LED RETROFIT  MODULE: 104°F (40

C); MAXIMUM 

AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140°F (60°C). 

  INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE RETROFITTED. 

  IF  UNCERTAIN,  CONTACT  VEGA  LIGHT  CONTROL  SYSTEMS  CUSTOMER  SERVICE  TO  EVALUATE  APPLICABILITY  TO 

FIXTURE. 

[email protected]

PHONE: 616-259-0700 

 

1. 

PRODUCT OVERVIEW 

1.1.  D4 Post Top Retrofit Specifications 

 

 

LED Light Engine 

  30W, 40W, 60W, and 80W Versions  

  2200K, 3000K, 4000K and 5000K CCT Available 

  Type 3 and Type 5 Available 

  True photometric performance through silicone optics 

  Dimming Options: 

 

0-10vdc dimming available 

 

Timer based overnight schedules 

 

Mechanical Details 

 

4.73” & 5.91” Diameter Light Engines fit ALL globes 

  Telescoping center post for height adjustment, field settable  

  Universal Mounting plates available in 4 sizes; 6.2

5”, 6.5”, 7” or 8” diameter  

  Brand specific quick change mounting plates also available  

  Power supply housing and bracket designs to mount above, midway, or below globe/fixture base  

  Downlight light option for suspended LED engine in shoeboxes, pendants, and colonials. 

Performance Details 

  5 Year replacement warranty, extended warranties available  

  18kA series surge suppression designed to UL1449 3rd edition 

  Drivers qualified to: 

 

 Life > 50,000 hours 

 

power factor of ≥0.9 

 

THD 

of ≤20% 

  LEDs qualified to: 

 

DLC Premium models 

– L70 of 100,000 hours minimum, L90 of 36,000 hours min. 

 

DLC Standard models 

– L70 better than 50,000 hours 

Summary of Contents for D4-C

Page 1: ...SDICTION RISQUE D INCENDIE OU DE CHOC LECTRIQUE L INSTALLATION DE CE N CESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILI RE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYST ME LECTRIQUE DU LUMINAIR...

Page 2: ...FIXTURE AMBIENT OPERATING TEMPERATURE FOR LED RETROFIT MODULE 104 F 40 C MAXIMUM AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140 F 60 C INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE R...

Page 3: ...plication Specific configuration for mounting in Granville Classic 7 and 4 fitters with 19 glass globes One piece assembly Granville Premier Kit Style Watts CCT Type Mounting Dimming Mounting Code Det...

Page 4: ...mm LED Light Engine Height Adjustable From 15 Down To 9 75 D4 F Model Fully Enclosed 60W Max Adapter Plate D4 S Down Light Model with Side Brackets D4 M Model Mid Mount Enclosed 80W Max 4 73 or 5 91...

Page 5: ...LexaLite Lindy 408 globe performs best at LED height set 8 from the base of the globe Crown 88266 CL has an optimum output when set 13 from the base of the globe 5 Measure the maximum temperature achi...

Page 6: ...efore servicing WARNING Risk of burn Allow unit to cool fully before servicing POST TOP Note Failure to remove original components including ballast will void product warranty Original optical compone...

Page 7: ...ght tighten set screw enough to hold tube then tighten another turn with hex key see 1 4 2 4 Side brackets can be adjusted bent trimmed or special ordered to span or offset LED mounting height Allow a...

Page 8: ...acing the street see 1 4 6 Re use screws previously holding HID ballast to fixture to attach Retrofit Kit when possible Additional hardware maybe required For Post Top fixtures LED Light should be ins...

Page 9: ...Black or Blue using pre installed Lever Nuts If photocell controlled or remote controlled connect Retrofit Kit to output of the control 2 5 STEP 5 Secure fixture components Secure fixture components a...

Page 10: ...rranty period contact VEGA sales representative for RMA 3 If out of warranty period contact VEGA sales representative for information to replace surge protector LEDs are dim or not lit 1 DC Cable is u...