Vega MT X CAN / User Manual
19
Revision 13 of 27.09.2021
FUEL LEVEL SENSORS
The monitoring device allows you to connect fuel level sensors via the RS-485 bus and operates with
them using the LLS protocol. To do this, you need to connect to the device through the “Configurator”
program and go to the “Settings” menu -> “Inputs/Outputs” tab. For each connected fuel level sensor, it is
necessary to select “Sensor Type” - RS-485 or RS-232 and specify the sensor address on the bus in the “Bus
Address” field. The specified address must match the address specified when the sensor programming (see
instructions for the used sensor).
Up to four fuel level sensors can be connected simultaneously.
Click the “Save” button to put information about sensors into device memory.