Vega MT X CAN / User Manual
16
Revision 13 of 27.09.2021
4 EXTERNAL EQUIPMENT CONNECTION
DALLAS TEMPERATURE SENSORS
Vega MT X CAN monitoring device allows to connect is up to ten Dallas temperature sensors
through 1-Wire interface. Connection scheme is on the picture below. If connected temperature sensor has
three contacts instead of two then you should close “Power” with “Ground”.
For the device to recognize the connection of a new sensor, it is necessary to connect to the device
through the "Configurator" program, go to the “Settings” menu -> "Inputs/outputs" tab and select the "Dallas
temperature sensors" setting item.
To distinguish sensors after connection, it is recommended to connect them one at a time. Having
connected the first sensor according to the diagram above, click the "Add sensors" button. An information
window will appear.