![background image](http://html1.mh-extra.com/html/vega-absolute/mt-5-can/mt-5-can_user-manual_3810850023.webp)
Vega MT-5 CAN/ User Manual
23
Revision № 04 of 01 July 2022
server - set the server
address
@PIN:serverY:addr:port
&
protocol
&
period
&
term
inal_addr
____________
Y – server number
addr – server address
port – server port
protocol – protocol type:
off
vega – engineering server
egts – EGTS server
egts_l1 – EGTS Light 1
egts_l2 – EGTS Light 2
wcombine – Wialon Combine server
wips – Wialon IPS server
ndtp – NDTP server
period – communication period with server
terminal_addr – device address for NDTP or
device ID for EGTS protocol
@2222:server3:193.193.165.1
65:20332
&
wips
&
0
&
90008
____________
PIN – 2222
Server number – 3
Server address –
193.193.165.165
Server port – 20332
Exchange protocol – Wialon
IPS
Communication period – 0
(constantly in touch)
NDTP address or EGTS
device ID – 90008
setapn - set APN
@PIN:setapn:apn
&
user
&
pass
____________
apn – APN
user – username
pass – password
@1234:setapn:internet.beelin
e.ru
&
beeline
&
beeline
____________
PIN – 1234
APN – internet.beeline.ru
Username – beeline
Password – beeline
info? - current device
state request
@PIN:info?
@1234:info?
____________
PIN – 1234
server? - request
monitoring server
settings
@PIN:server?
@4444:server?
____________
PIN – 4444
runcanscript – run CAN
script number Х
@PIN:runcanscriptX
Х – CAN number that is needed to run
@4444:runcanscript3
____________
PIN – 4444
CAN script number 3