Vega MT-5 CAN/ User Manual
17
Revision № 04 of 01 July 2022
Click the “Save” button to put information about sensors into device memory.
EXTENSION UNIT
The Vega MT-5 CAN GNSS tracker allows you to connect the Vega BR-1 expansion unit via the RS-485
interface. Vega BR-1 has 15 multifunction inputs and 15 digital outputs.
To configure the inputs, you must connect to the device through the “Configurator” program, go to
the “Settings” menu -> “Inputs/Outputs” tab and select the “Input/output extension unit”. Next, you need to
select the connection interface - RS-485. After that, you can configure
multifunctional inputs
in accordance
with the desired tasks.
To configure the outputs, it is necessary to connect to the device through the “Configurator” program,
go to the “State” menu -> “Input/output expansion unit” tab. At the very bottom of the I/O list of the expansion
unit are the digital output controls - the “On” and “Off” buttons.
ACTUATORS
Actuators are connected to the device via digital output which are of the type “Open collector”.
So, for example, you can connect a relay for blocking the engine/petrol pump/ignition, etc. After
connecting the relay according to the scheme, you can send commands to the device to block or unblock
the relay (see the section
"SMS commands"
, command setout).
Permissible load on each digital output 0.5 A