Vector TLR-D5P-U SeriesTLR-D5P-24 Engineering Manual Download Page 3

 

TLR-D5P-U Engineering Manual

 

 

Doc: 70-07-0100, V2.2, Date: 20090201 

©2008 Vector Controls 

Page 3 

Technical specifications 

Power Supply 

Operating Voltage 

 TLR-D5P-U-24 
 TLR-D5P-U-230 

 

24 V AC ± 10 %, 50…60 Hz 

230 V AC ± 10 %, 50…60 Hz 

Power Consumption 

 TLR-D5P-U-24 

 TLR-D5P-U-230 

 

Max. 3 VA 

Max. 5 VA 

Electrical Connection 

Terminal Connectors, wire 0.34…2.5 mm

2

 (AWG 24…12)

 

Internal rectification:  

Full wave rectified  

Deluxe type only: 

Power backup for real time clock 

 

Min 48 hours if charged for 24 hours 

Signal inputs 

Temperature Input 

 

Range 

Int. NTC: 0…50 °C (32…122 °F) 
Ext. NTC (Sxx-Tn10 sensor): -20…70 °C (-4…158 °F) 

Accuracy 

-20…0 °C (-4…32 °F): 0.5 K 
0…50 °C (32…122 °F): 0.2 K 

50…70 °C (122…158 °F): 0.5 K 

Signal outputs 

Relays Outputs  
AC Voltage  

Insulation resistance 

DO1…DO5 
0…250 VAC, 10 (6) A max. each output  

3750 VAC acc. to EN 60 730-1 

Communication  

Base - Terminal 

Communication Type 
Cable Type 
Max Distance 

Digital: peer to peer 
Copper wire 0.8…2.5 mm

2

 (AWG18…AWG13) 

200m (650ft) use shielded wire in an EMC challenged 
environment. Conductor resistance must be compensated 
if external sensor is used 

Environment 

Operation 

Climatic Conditions 

Temperature 
Humidity 

To IEC 721-3-3 

class 3 K5 

0…50 °C (32…122 °F) 
<95 % r.H. non-condensing 

Transport & Storage 

Climatic Conditions 
Temperature 
Humidity 

Mechanical Conditions 

To IEC 721-3-2 and IEC 721-3-1 

class 3 K3 and class 1 K3 
-25…70 °C (-13…158 °F) 
<95 % r.H. non-condensing 
class 2M2 

Standards 

conform according to  

EMC Standard 89/336/EEC 
EMEI Standard 73/23/EEC 

 

EN 61 000-6-1/ EN 61 000-6-3 

Product standards 

Automatic electrical controls for household and 
similar use 

Special requirement on temperature dependent 

controls 

 

EN 60 730 –1 
 

EN 60 730 – 2 – 9 

General 

Terminal 

Degree of Protection 

IP30 to EN 60 529 

Safety Class 

III (IEC 60536) 

Housing Material 

Cover, back part 
Mounting Plate 

 

Fire proof ABS plastic (UL94 class V-0) 
Galvanized Steel 

Color 

White RAL 9003 

Dimensions (H x W x D) 

112 x 73 x 15 mm (4.4” x 2.9” x 0.7”) 

 

Weight (controller only) 

70 g (2.8 oz) 

General Base 

Degree of Protection 

IP30 to EN 60 529 

 

Safety Class 

Base: II (IEC 60536) 

 

Housing Material 

Fire proof ABS plastic (UL94 class V-0) 

 

Color 

Gray (RAL 7001 / 7035) 

 

Dimensions (H x W x D) 

57 x 147 x 115 mm (2.25 x 5.8 x 4.5 in) 

Weight 

including package, base + terminal) 

TLR-D5P-U-24 
TLR-D5P-U-230 

 

520 g (1.15 lb) 
570 g (1.25 lb) 

 
 

Summary of Contents for TLR-D5P-U SeriesTLR-D5P-24

Page 1: ...oost and delayed switching on or off Features Temperature control for 2 or 4 pipe package units 2 stages fan supported heating or cooling with reversing valve Temperature control for 2 pipe package un...

Page 2: ...it only 24V OPR 1 40 50 0001 2xAAA bat Remote controller S Tn10 2 SD Tn10 12 2 SD Tn10 20 2 SDB Tn10 12 SDB Tn10 20 SRA Tn10 SOA Tn10 40 20 0001 40 20 0002 40 20 0003 40 20 0051 40 20 0004 40 20 0005...

Page 3: ...if external sensor is used Environment Operation Climatic Conditions Temperature Humidity To IEC 721 3 3 class 3 K5 0 50 C 32 122 F 95 r H non condensing Transport Storage Climatic Conditions Temperat...

Page 4: ...startup currents may be a multiple of the rated current of the fan Verify with the fan supplier if unclear Do not connect directly motors larger than 1kW Connection diagram Connection terminals Power...

Page 5: ...t to the wall or the flush mounting box Make sure that the nipple with the front holding screw is facing to the ground Make sure the screw heads do not stand out more than 5 mm of the surface of the m...

Page 6: ...rsion includes a real time clock with a 48h backup battery powered through a super capacitor The time does not need to be re entered after a power failure Frost Protection The controller will enter fr...

Page 7: ...s is to avoid unnecessary heating or cooling of such rooms while they are not occupied Override reset function The override reset applies when the unit is manually switched on while in scheduled off m...

Page 8: ...etup Time schedule The menu may be left by pressing the POWER button or by not pressing a button for more than 5 minutes Heat Cool Fan only change Pressing the OPTION button toggles Heating Cooling Fa...

Page 9: ...t points for the temperature loop may be changed Set point range is 15 to 30 C Boost Pressing the boost button activates a 5 minute boost The output will be fully opened for the period of 5 minutes in...

Page 10: ...order to return to the parameter selection level 9 Press the POWER button again so as to leave the menu The unit will return to normal operation if no button is pressed for more than 5 minutes User P...

Page 11: ...d change is reversed The aim is to avoid unnecessary switching of fan speeds and thus to increase the life span of fan and relays Mold Protection The fan will not stop when the setpoint is reached whi...

Page 12: ...ing on delay will be reset after a heat cool change This will allow a reversing valve to open before a compressor starts Enough time will therefore be required for the delay on parameter Delay on reve...

Page 13: ...on detectors for offices Remote enable Opening the external temperature input will force the unit into the OFF operation mode The operation mode cannot be overridden by using the terminal or time sche...

Page 14: ...display the firmware version can be found on the lower 7 segment display the current revision index or sub version Accessing the control parameters Warning Only experts should change these settings Th...

Page 15: ...n heating cooling set point XDZ 0 100 C 200 F 1 0 C 2 F CP 13 Delay on Heat Cool change over 0 255 min 5 min Input configuration Parameter Description Range Default CP 14 External input 0 No external...

Reviews: