background image

1

AUTOMATIC 

BATTERY CHARGER

OWNER’S MANUAL & WARRANTY INFORMATION

12 VOLT 2/10/20/40 AMPERE CHARGE RATES WITH 100 AMP ENGINE START,

ALTERNATOR VOLTAGE CHECK AND BATTERY RECONDITON FUNCTIONS

• IMPORTANT SAFETY INSTRUCTIONS •

WARNING – RISK OF EXPLOSIVE GASES

1. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES 

GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS 

REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR 

CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.

2. To reduce risk of battery explosion, follow these instructions and those published by the battery 

manufacturer and manufacturer of any equipment you intend to use in vicinity of battery. Review 

cautionary markings on these products and on engine.

GENERAL BATTERY SAFETY

1. Use charger for charging a LEAD-ACID battery only. It is not intended to supply power to a low volt-

age electrical system other than in automotive applications. Do not use battery charger for other types

of batteries, these may burst and cause injury to persons and damage to property.

2. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a

risk of fire, electric shock, or injury to persons.

3. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when 

disconnecting charger.

4. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord

could result in a risk of fire and electric shock. If extension cord must be used, make sure:

a. That pins on plug of extension cord are the same number, size, and shape as those of 

plug on charger.

b. That extension cord is properly wired and in good electrical condition; and

c. That wire size is AWG #10 (10 gauge) to 100 feet and AWG #8 for distances over 100 feet.

5. Do not operate charger with damaged cord or plug - replace the cord or plug immediately.

6. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any

way; take it to a qualified service technician.

7. Do not disassemble charger; take it to a qualified service technician when service or repair is

required. Incorrect reassembly may result in a risk of electric shock or fire.

8. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or

cleaning. Turning off controls will not reduce this risk.

9. Do not expose charger to rain or snow.

10. Never charge a frozen battery.

SAVE THESE INSTRUCTIONS:

This manual contains important safety and operating instructions for battery charger Model VEC093

4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312 • TEL: 954-584-4448 • FAX: 954-584-5556 • TOLL-FREE 866-584-5504

VEC093

A062003

Summary of Contents for A062003

Page 1: ...duce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b Th...

Page 2: ... The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances See Figure 1 DANGER NEVER alter AC cord or plug provided if it will not fit outlet have proper outlet installed by a qualified electrician Improper connection can result in the risk of an electric shock This battery charger is for use on a nominal 120 volt circuit has ...

Page 3: ...tric outlet 2 Never allow clips to touch each other 3 Attach clips to battery posts and twist or rock back and forth several times to make a good connection This tends to keep clips from slipping off terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Positio...

Page 4: ...he CHARGING COMPLETE LED lights to indicate charging operation is complete FIGURE 2 CHARGE CURVE FEATURES The unit has four charge rate settings with a 2 10 20 40 pushbutton charge rate switch a 2 amps smaller batteries as in lawn mowers snowmobiles motorcycles etc b 10 amps middle sized batteries such as in small cars c 20 amps automobile batteries d 40 amps large truck batteries banks of RV batt...

Page 5: ...ing mode and the display shows the circulating pattern Figure 4B Alternator Voltage Check enables a five second check that measures the battery voltage This check is repeat ed at various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads It can indicate alternator service may be required Battery Recondition is an automatic mode that once s...

Page 6: ...ear of the charger for handy reference FIGURE 5 Below the Digital Display are a series of four LEDS that light on the following conditions FAULT lights when a any of several faults are detected see F01 through F05 Codes as described above If the Fault LED lights refer to TROUBLESHOOTING for details REV POLARITY Lights when the clamps are connected to incorrect polarity Charging Complete lights at ...

Page 7: ...mp to the vehicle chassis or the engine block away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body parts connect only to a heavy gauge metal part of the frame or engine block NOTE NEGATIVE GROUNDED type systems are the most common in today s vehicles c Set charger s Charge Rate to appropriate setting 2 10 20 40A according to battery size POSITIVE GROUNDED...

Page 8: ... to 000 This initial charge on the battery makes sure that the battery is able to take a charge When the 000 count is reached the Start Your Engine LED lights This indicates that the high current circuit is enabled and will energize when the engine starts cranking Crank the engine using manufacturer s guidelines typically in 3 to 5 second bursts The high current engine starting function requires a...

Page 9: ...hen the ON OFF button is pressed to stop the check Alternator Voltage Check is then repeated after many appliances are turned on to check the alternator output under a greater load If the first unloaded and second loaded checks indicate the alternator is good then the entire procedure should be repeated again If after all appliances are turned on except for air conditioning and defroster and the c...

Page 10: ...ure that the battery is not sulfated Check that the correct charge rate has been selected for the battery being charged Ensure that enough charging time has been allowed for check table in Appendix A for approximate charging times VERY COLD BATTERY If the battery to be charged is extremely cold in temperatures less than freezing 0º C 32º F it cannot accept a high rate of charge so the initial char...

Page 11: ...erage automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged battery divide the AH rating of the battery by the charge rate selected This is the number of hours required to recharge the battery For example a 50 AH 12 volt battery is discharged 10 volts How long sho...

Page 12: ...ATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood a...