4.3  CONNECTION TO LOAD

The MAXX 750 SST is equipped with dual standard North American AC power

receptacles. Plug the cord from the equipment you wish to operate into the 

AC receptacle(s). The green LED indicator lights to indicate that the inverter is

functioning. Make sure the combined load requirement of your equipment does

not exceed 750 watts.
The MAXX 750 SST is engineered to be connected directly to standard electrical

and electronic equipment in the manner described above. Do not connect the

power inverter to household or RV AC distribution wiring. Do not connect the

power inverter to any AC load circuit in which the neutral conductor is connected

to ground (earth) or to the negative of the DC (battery) source.

WARNING:

Do not connect to AC distribution wiring!

CAUTION:

RECHARGEABLE APPLIANCES-Certain rechargeable devices are designed

to be recharged only by plugging them directly into an AC receptacle.

These devices may damage the inverter. Do not use the inverter to

recharge items that can only be plugged directly into an AC receptacle.

This problem does not occur with the majority of battery-operated equipment.

Most of these devices use a separate charger or transformer that is plugged into

an AC receptacle. The MAXX 750 SST is easily capable of running most charg-

ers and transformers.

4.4 PLACEMENT OF THE INVERTER

For best operating results, the inverter should be placed on a flat and/or  solid

surface. A power cord measuring 3 feet (1.0 meter) has been provided for easy

positioning of the inverter. The inverter should only be used in locations that meet

the following criteria:
DRY - Do not allow water and/or other liquids to come into contact with the

MAXX 750 SST inverter.
COOL - Ambient air temperature should be between 30°F (-1°C) non-condensing,

and 105°F (40°C). Do not place the inverter on or near a heating vent or any

piece of equipment which is generating heat above room temperature. Keep the

inverter away from direct sunlight, if at all possible.
VENTILATED - Keep the area surrounding the inverter clear to ensure free air 

circulation around the unit. Do not place items on or over the inverter during 

operation. A fan is helpful if the inverter is operating at maximum power outputs

for extended periods of time. The unit will shut down if the internal temperature

exceeds operating temperatures. The unit will restart after it cools.

SAFE - Do not use the inverter near flammable materials or in any

locations that may accumulate flammable fumes or gases.

8

Summary of Contents for 750 Watt Power Inverter

Page 1: ...UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28th Way FT...

Page 2: ...connections and ring terminal connections This is not a toy keep away from children CAUTIONS Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks and boats...

Page 3: ...tion 6 4 1 Power source requirements 6 4 2 Connection to power source 6 7 4 3 Connection to load 8 4 4 Placement of inverter 8 5 Operating tips 9 5 1 Rated versus actual current draw of equipment 9 5...

Page 4: ...l voltage ramp up during inverter start up This eliminates failed cold starts under load Second output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start Thi...

Page 5: ...ulky transformers found in less technological ly advanced models The inverter stage uses advanced power MOSFET transistors in a full bridge configuration This ensures excellent overload capability and...

Page 6: ...able to supply the necessary current to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the current in amperes the power source mu...

Page 7: ...t breaker close to the DC power source battery terminal 1 Check to be sure the inverter s power switch is turned off and that no flammable fumes are present 2 Identify the positive and negative DC pow...

Page 8: ...se devices use a separate charger or transformer that is plugged into an AC receptacle The MAXX 750 SST is easily capable of running most charg ers and transformers 4 4 PLACEMENT OF THE INVERTER For b...

Page 9: ...er will not operate high wattage appliances or equipment that produce heat such as hair dryers microwave ovens and toasters 5 2 BATTERY OPERATING TIME With a typical vehicle battery a minimum operatin...

Page 10: ...uide The alarm will sound when the inverter is overloaded in thermal shutdown or if there is an excessive voltage drop between the battery and inverter NOTE It is normal for the alarm to sound while t...

Page 11: ...ive Operate an correct speed incandescent lamp at same time as motor Television radio Snow in picture buzz Keep inverter and interference in speaker antenna distant from each other Use shielded antenn...

Page 12: ...d workmanship for two years from the date of purchase without additional charge The warranty does not extend to subsequent purchasers or users Vector Manufacturing Ltd will not be responsible for any...

Page 13: ...tormfg com for general repair information and charges if applicable STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limitations on how long an implied warranty...

Page 14: ...2004 Vector Manufacturing Ltd FT LAUDERDALE FL 33312 Made in China...