10. SPECIFICATIONS

Output Connection   . . . . . . Dual North American Standard Receptacles
Output Voltage  . . . . . . . . . . . . . . . . Approx 110  volt AC RMS 60 Hz
Output Current  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8 Amps
Output Waveform  . . . . . . . . . . . . . . . . . . . . . . . . Modified Sine Wave
Input Voltage Range  . . . . . . . . . . . . . . . . . . . . . . 10.5 to 15.5 volt DC
Low Voltage Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.6 volt DC
Low Voltage Shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . 10.0 volt DC
Input Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal
Input Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Battery Clip Cable
Additional Protection  . . . . . . . . . . . . . . Overload, Overvolt, Overtemp
Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lbs (1.36 kg)
Length   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.7 in. (27.2 cm)
Width   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25 in. (15.9 cm)
Height  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.75 in.  (4.5 cm)

9. WARRANTY

2 YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets

forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product.

There are no other warranties, other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only,

to be free of defects in materials and workmanship for two years from the date of

purchase without additional charge. The warranty does not extend to subsequent

purchasers or users. Vector Manufacturing, Ltd. will not be responsible for any

amount of damage in excess of the retail purchase price of the product under any

circumstances. Incidental and consequential damages are specifically excluded from

coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to

accessories or damage to units from misuse or incorrect installation. Misuse

includes wiring or connecting to improper polarity power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may 

be returned postage prepaid to Vector Manufacturing. Any defective product,

other than accessories, that is returned to Vector Manufacturing within 30 days 

of the date of purchase will be replaced free of charge. If such a product is

returned more than 30 days but less than two years from the purchase date,

Vector Manufacturing will repair the unit, at its option, or replace it free of charge.

12

Summary of Contents for 750 Watt Power Inverter

Page 1: ...UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28th Way FT...

Page 2: ...connections and ring terminal connections This is not a toy keep away from children CAUTIONS Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks and boats...

Page 3: ...tion 6 4 1 Power source requirements 6 4 2 Connection to power source 6 7 4 3 Connection to load 8 4 4 Placement of inverter 8 5 Operating tips 9 5 1 Rated versus actual current draw of equipment 9 5...

Page 4: ...l voltage ramp up during inverter start up This eliminates failed cold starts under load Second output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start Thi...

Page 5: ...ulky transformers found in less technological ly advanced models The inverter stage uses advanced power MOSFET transistors in a full bridge configuration This ensures excellent overload capability and...

Page 6: ...able to supply the necessary current to operate the load The power source may be a battery or a well regulated DC power supply To obtain a rough estimate of the current in amperes the power source mu...

Page 7: ...t breaker close to the DC power source battery terminal 1 Check to be sure the inverter s power switch is turned off and that no flammable fumes are present 2 Identify the positive and negative DC pow...

Page 8: ...se devices use a separate charger or transformer that is plugged into an AC receptacle The MAXX 750 SST is easily capable of running most charg ers and transformers 4 4 PLACEMENT OF THE INVERTER For b...

Page 9: ...er will not operate high wattage appliances or equipment that produce heat such as hair dryers microwave ovens and toasters 5 2 BATTERY OPERATING TIME With a typical vehicle battery a minimum operatin...

Page 10: ...uide The alarm will sound when the inverter is overloaded in thermal shutdown or if there is an excessive voltage drop between the battery and inverter NOTE It is normal for the alarm to sound while t...

Page 11: ...ive Operate an correct speed incandescent lamp at same time as motor Television radio Snow in picture buzz Keep inverter and interference in speaker antenna distant from each other Use shielded antenn...

Page 12: ...d workmanship for two years from the date of purchase without additional charge The warranty does not extend to subsequent purchasers or users Vector Manufacturing Ltd will not be responsible for any...

Page 13: ...tormfg com for general repair information and charges if applicable STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limitations on how long an implied warranty...

Page 14: ...2004 Vector Manufacturing Ltd FT LAUDERDALE FL 33312 Made in China...