Safety

• Always keep the dehumidifier in vertical position.
• When used in bath/shower rooms, the dehumidifier must be placed at least 0,6 m from 

the bathtub or shower cabin.

• Leave the unit to stand for one hour before connecting to the mains supply after transport 

or when it has been tilted (e.g. during cleaning).

• Allow a free space of 15 cm around the unit.
• Keep all foreign objects away from the air intake and outlet openings.
• Keep the unit away from heaters or other heat-producing equipment.
• Never pour or spray water over the unit.
• The mains supply must conform with the voltage specified on the rating label.
• Never use the plug to start or stop the dehumidifier. Always use the switch on the control 

panel.

• Before moving the unit, switch it off, pull the plug and empty the water tank.
• Clean the air filter when needed. The dehumidifier is  most effective when the filter is 

clean.

• Don’t use sprays or other flammable cleaners on the product.
• If the dehumidifier breaks down, please turn it off and then pull the plug.
• If the supply cord is damaged it must be replaced by an approved and qualified person.

Function

This dehumidifier regulates the relative humidity by passing the air through the unit, forcing 
the excess moisture to condensate over the cooling element (evaporator). The excess 
moisture is turned to water and drained into the water tank.  The dried air then passes 
through the condenser where it is slightly warmed, and re-enters the room at a somewhat 
higher temperature.

Applications

LAF 10 is designed to remove humidity from the air, creating a healthy and comfortable 
indoor climate. The dehumidifier is suitable for use in basements, cellars, storage rooms, 
kitchens, libraries, galleries, computer rooms etc. 

Condenser

Evaporator

Water tank

Compressor

Moist 
saturated air

Dry 
warmer 
air

Summary of Contents for LAF 10

Page 1: ...2 Instruction manual Important Read these instruction before the product is installed and used Save the instructions for future use 6 Bedienungsanleitung Wichtig Lesen Sie die Anleitung durch bevor S...

Page 2: ...ltret vid behov Avfuktaren arbetar mer effektivt om filtret r rent Anv nd aldrig l ttant ndliga v tskor vid reng ring Om avfuktaren slutar fungera st ng av den och dra ut kontakten Skulle skada uppst...

Page 3: ...aka vattenbeh llaren i r tt l ge efter t mning OBS Om beh llaren inte r korrekt insatt kommer Water Full indikatorn fortfarande att lysa r tt B Fig 5 Fig 6 Fig 7 A Alternativt Avfuktaren kan anslutas...

Page 4: ...gsf rh llandena Kontrollera filtret med j mna mellanrum och byt till ett nytt vid behov F rvaring Om avfuktaren inte anv nds under en l ngre tid St ng av apparaten dra ut kontakten och reng r avfuktar...

Page 5: ...10 Sp nning 230V 50Hz Arbetstemperatur 8 till 35 C Kylmedel R 134a M ngd kylmedel 150 g Avfuktningskapacitet 5 liter dygn vid f rh llanden RT27 C RH 60 10 liter dygn vid f rh llanden RT30 C RH 80 Vat...

Page 6: ...air filter when needed The dehumidifier is most effective when the filter is clean Don t use sprays or other flammable cleaners on the product If the dehumidifier breaks down please turn it off and th...

Page 7: ...s and then out for easy removal After emptying the tank push it back into position Note If the tank doesn t position well the Water Full indicator will still light red Optional The dehumidifier LAF 10...

Page 8: ...on the ambient conditions where the unit is used The filter should be checked periodically and replaced if necessary Storage If the dehumidifier is not used for a longer period of time please Turn th...

Page 9: ...at RT 27 C RH 60 10 liters per day at RT 30 C RH 80 Water container volume 4 0 l Power 220 W RT20 C RH 60 Current 1 3 A Net weight 13 5 kg Dimensions 270 x 550 x 364 mm B x H x D Protection class IP...

Page 10: ...en Sie bei Bedarf den Luftfilter Der Entfeuchter arbeitet effektiver wenn der Filter sauber ist Verwenden Sie keine leicht entflammbaren Reinigungsmittel bei der Reinigung des Ger tes Setzt der Entfeu...

Page 11: ...ren wieder in die richtige Lage Achtung Sitzt der Beh lter nicht korrekt wird die Signallampe f r Water Full weiter rot leuchten Alternative An den Kondensatbeh lter kann wie folgt ein Schlauch angesc...

Page 12: ...ren Sie deshalb den Filter regelm ig und tauschen sie ihn bei Bedarf gegen einen neuen aus Aufbewahrung Falls der Entfeuchter l ngere Zeit nicht verwendet wird Schalten Sie das Ger t aus ziehen Sie de...

Page 13: ...230V 50Hz Arbeitstemperatur 8 bis 35 C K ltemittel R 134a Menge K ltemittel 150 g Leistung 5 Liter Tag bei 27 C Raumtemperatur 60 Luftfeuchtigkeit 10 Liter Tag bei 30 C Raumtemperatur 80 Luftfeuchtigk...

Page 14: ...14 K e ca VEAB 15 0 6 OFF OFF LAF10 LAF 10 RU...

Page 15: ...15 Fig 1 Fig 2 Fig 3 Fig 4 MAX Fig 1 Fig 2 OFF Fig 3 LAF10 HI LO HI LO Fig 4 B Fig 5 Fig 6 Fig 7 A LAF 10 Fig 5 6 Fig 6 Fig 7...

Page 16: ...16 Fig 8 Fig 9 Fig 10 C 2 1 2 Fig 8 Fig 9 Fig 10 80...

Page 17: ...17 4 5 6 1 2 3 1 2 3 4 5 6 LAF 10 230 50 8 35 R 134a 150 5 27 60 10 30 80 220 20 60 1 3 13 5 270 550 364 IP 21...

Page 18: ...18...

Page 19: ...19...

Page 20: ...www am tryck se...

Reviews: