background image

Designed for drying water-based paints. Panel dryer operates on workshop air supply. Filter prevents
airborne particles contaminating paint surface. Ideal for localized or spot repair. May be hand-held or
mounted on optional Double Support Stand Model No. SDAST

Instructions For:

AIR OPERATED 
PANEL DRYER

Model:

SDA01

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.

Max Working Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90psi
Air Consumption:    . . . . . . . . . . . . .10cfm @ 15psi, 18cfm @ 90psi
Air Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4" BSP

IMPORTANT: 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL

REQUIREMENTS, WARNINGS AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE 
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY,
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.

SAFETY INSTRUCTIONS

!

Familiarise yourself with this products application and limitations.

"

WARNING!

Disconnect the dryer from the air supply before performing any maintenance.

!

Maintain the dryer in good condition (use an authorised service agent).

!

Replace or repair damaged parts. 

Use recommended parts only. Unauthorised 

parts may be dangerous and will invalidate the warranty.

!

Locate the dryer in an adequate working area for its function, keep area clean 
and tidy and free from unrelated materials, and ensure there is adequate 
ventilation and lighting.

!

Keep the dryer clean for best and safest performance.

!

Ensure the air system is suitable to the dryer consumption, (see specifications).

!

Keep children and unauthorised persons away from the working area.

!

When not in use ensure the air supply is turned off.

#

DO NOT use the dryer for any purpose other than for which it is designed.

#

DO NOT operate dryer if any parts are missing or damaged as this may cause 
failure or personal injury.

#

DO NOT direct air from the air hose at yourself or others.

!

When not in use switch the dryer off, and disconnect from the air supply. 

3.

AIR SUPPLY CONNECTION

Fig. 1

Fig. 2

3.1.

Air Supply

Recommended hook-up procedure is shown in (Fig. 1).
3.1.1.

Ensure dryer air valve is in the ‘OFF’ position before connecting to the air supply.

3.1.2.

You will require air pressure and air flow according to specification.

"

WARNING! 

Ensure the air supply is clean and does not exceed 90 psi while operating the dryer. Too high an air pressure and 

unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
3.1.3.

Drain the air tank daily. Water in the air line will damage the dryer.

3.1.4.

Clean air inlet filter weekly.

3.1.5.

Keep hoses away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.

3.2.   Couplings.

Movement can cause failure if a quick change coupling is connected directly to the dryer when used without optional stand, Model No.
SDAST. To overcome this, connect a leader hose to the dryer. A quick change coupling may then be used to connect the leader hose
to the air line recoil hose (See Fig. 1 & 2). 

2.    INTRODUCTION AND SPECIFICATION

SDA01 - 1 - 011206