![vc999 RS420 Maintenance Manual Download Page 41](http://html2.mh-extra.com/html/vc999/rs420/rs420_maintenance-manual_3674555041.webp)
TROUBLESHOOTING GUIDE
ALARM SCREEN MESSAGES
CHECK TRIM CANISTER
•
Check overload switch on the bottom of the trim canister
•
Check if trim canister is full
•
Make sure hoses are not blocked
•
Make sure trim canister is plugged in
•
Check electrical plug
MAIN DRIVE OVERLOAD
•
Check drive motor
•
Check trim wound around sprockets
•
Check chain for jam or deformation
•
Check contactor and reset it
ROTARY KNIFE BREAKER
•
Check knife for jam
•
Check blades for dull edges or nick's
•
Check rotary knife motor
•
Reset the breaker
VACUUM PUMP OVERLOAD
•
Check oil vacuum pump
•
Check motor on vacuum pump
E-STOP
•
Reset depressed e-stop
•
Check e-stop switch
•
Loose or broken wire on e-stop
ERROR ON 4AD
•
Check for 24V DC to the module
•
Check led input / output
ERROR ON 4ADTC
•
Check for 24V DC to the module
•
Check led input / output