Doc. # 01
-
04
-
033A
1)
Inspection of LED light Bars. Lift the lid
and override the safety switch on the
left side of the cabinet by depressing
with your finger or a pencil. Put your
sunglasses on and hit RUN from the
setup screen. With the lid up view if ALL
lights are working. If not, proceed to
step 2. Contact factory for replacement
light bar.
It may be possible to expose screens with
LED lights out, but a repair is needed to
ensure optimal performance.
Troubleshooting Cont’d
Light Bar Replacement / Installation
2)
Unplug main power cord.
3)
Remove exposing unit glass, see
Maintenance section for glass removal.
4)
Open the maintenance door in the front
of the unit by removing the (4) #8 sheet
metal screws with a 1/4” driver.
5)
Disconnect the defective light bar
connector (each bar has its own
connector), then remove the top, #8 nut
holding down the light bar.
6)
Installing the new light bar. Seat the
light bar in its corresponding slot.
7)
Test the new light bar. See above
section 1.
8)
Secure the bar with the #8 nut and
attach the connector.
9)
Close the maintenance door and
replace the #8 sheet metal screws.
Slot in back
Step 6
Light bar connector
#8 nut
Light bar
Step 5
Maintenance door
Step 4
Depress Limit
Switch when
testing lights
Step 1
Note:
It is important to wear dark shaded and UV rated
eye protection while testing any UV Lights.
Do Not allow objects to contact the UV lights.
Pg. 11