Saving settings as a preset:

 

1)

 

On the setup screen, select SAVE PRESET.

 

2)

 

Select a letter to save the preset to.

 

Settings currently stored to the letter 
selected will be shown on the right.  Confirm 
all settings before overwriting a preset.

 

3)

 

To cancel saving a preset, press the X in the 
upper right corner.

 

Load Preset Screen

 

Preset slot

 

Return to home screen

 

Settings currently 
saved in selected 
preset

 

Save Preset Screen

 

Preset slot

 

Return to setup screen

 

Settings currently 
saved in selected 
preset

 

Error messages:

 

Your exposing unit could prompt you with several warnings and error messages if triggered.

 

WAITING FOR CLOSED LID

 

The lid is in the upright position when Run was selected.  Press CANCEL.  Lower and lock the lid before 
pressing RUN to remove the warning.

 

EXPOSURE INCOMPLETE: LID WAS OPENED

 

The lid was opened before the exposure cycle completed.  The lid must remain closed for the duration of 
the exposure cycle.  If the error occurs during the exposing part of the cycle, it is recommended to restart 
the exposure with a fresh screen.

 

EXPOSURE INCOMPLETE: POWER FAILURE

 

A power failure occurred during an exposure cycle.  Loss of power to the unit or from the power supply will 
trigger this error.  If the error occurs during the exposing part of the cycle, it is recommended to restart the 
exposure with a fresh screen.

 

Loading a saved preset:

 

1)

 

From the home screen, choose SELECT 
PRESET.

 

2)

 

Select the desired preset.

 

Settings saved in the preset are shown on 
the right side.

 

3)

 

Select LOAD to load the desired preset.

 

4)

 

To return to the home screen, select the X in 
the upper right corner.

 

Pg. 8

Summary of Contents for E-1000

Page 1: ...and date of purchase for future reference Date Electrical Drawing Revision Vastex E mail assistance Purchasing Product Info sales vastex com Electrical Support stech vastex com Tech Support Mechanica...

Page 2: ...Rocking Piston Pump 120 240V P N 04 02 060 1 4 HP Rocking Piston Pump 120 240V P N 04 02 060 1 4 HP Rocking Piston Pump 120 240V P N 04 02 060 1 4 HP Rocking Piston Pump 120 240V P N 04 02 060 Control...

Page 3: ...or entering control box Do not operate if any guard or cover has been removed Do not operate if power cord is damaged Safe Operating Temperature Ambient 55 F 100 F 13 C 38 C Do not attempt to defeat s...

Page 4: ...6 8 For troubleshooting and maintenance instructions see pages 9 12 Stability during use transportation assembling dismantling when out of service testing and foreseeable breakdowns This equipment is...

Page 5: ...t over tighten 1 Install legs if included Place Legs on a clear spot on the floor 28 5 72 5cm apart as shown in picture 1 2 Lock lid handles as shown Carefully lower the exposing unit down onto the le...

Page 6: ...for each size screen Lock lid and set vacuum time to 90 Seconds Start cycle and record the time it takes to flatten the blanket to a size larger than your positive If unsure wait until blanket is fla...

Page 7: ...desired time 4 Press ENTER to confirm selection Setting the exposure time 1 From the setup screen press the number under the label EXPOSURE 2 Enter a time from 0 999 seconds 3 Press DELETE enough time...

Page 8: ...ected Press CANCEL Lower and lock the lid before pressing RUN to remove the warning EXPOSURE INCOMPLETE LID WAS OPENED The lid was opened before the exposure cycle completed The lid must remain closed...

Page 9: ...the cabinet and between the side retainers Slide glass back until it contacts and it seated squarely against the back seal Place the front glass retainer and the three cams against the glass front Ins...

Page 10: ...ust the lid lower Proceed as follows pictures below for reference a Remove both Lid Lifting Cylinders from their upper mounting stud Carefully lower the lid b Rear Seal Adjustment Start with the lid d...

Page 11: ...r glass removal 4 Open the maintenance door in the front of the unit by removing the 4 8 sheet metal screws with a 1 4 driver 5 Disconnect the defective light bar connector each bar has its own connec...

Page 12: ...ory for replacement lights Troubleshooting Cont d UV Black Light Bulb Replacement Installation 2 Unplug main power cord 3 Remove exposing unit glass see Maintenance section for glass removal 4 Open th...

Page 13: ...io will prevent a good gasket seal prevent good detail resolution and increase chances of saw tooth edges Manufacturers recommend an EOM ratio of 10 to 20 percent With an emulsion stencil more is not...

Page 14: ...st Rz numbers possible and can save large amounts of screen room production time Fig 6 Capillary films are best applied with the emulsion up on a hard flat surface Fig 7 Fig 7 Place a screen squeegee...

Page 15: ...licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to accept...

Reviews: