Doc. # 01
-
04
-
033A
Operation Cont’d
Saving settings as a preset:
1)
On the setup screen, select SAVE PRESET.
2)
Select a letter to save the preset to.
Settings currently stored to the letter
selected will be shown on the right. Confirm
all settings before overwriting a preset.
3)
To cancel saving a preset, press the X in the
upper right corner.
Load Preset Screen
Preset slot
Return to home screen
Settings currently
saved in selected
preset
Save Preset Screen
Preset slot
Return to setup screen
Settings currently
saved in selected
preset
Error messages:
Your exposing unit could prompt you with several warnings and error messages if triggered.
WAITING FOR CLOSED LID
The lid is in the upright position when Run was selected. Press CANCEL. Lower and lock the lid before
pressing RUN to remove the warning.
EXPOSURE INCOMPLETE: LID WAS OPENED
The lid was opened before the exposure cycle completed. The lid must remain closed for the duration of
the exposure cycle. If the error occurs during the exposing part of the cycle, it is recommended to restart
the exposure with a fresh screen.
EXPOSURE INCOMPLETE: POWER FAILURE
A power failure occurred during an exposure cycle. Loss of power to the unit or from the power supply will
trigger this error. If the error occurs during the exposing part of the cycle, it is recommended to restart the
exposure with a fresh screen.
Loading a saved preset:
1)
From the home screen, choose SELECT
PRESET.
2)
Select the desired preset.
Settings saved in the preset are shown on
the right side.
3)
Select LOAD to load the desired preset.
4)
To return to the home screen, select the X in
the upper right corner.