COEFFICIENT OF PERFORMANCE
20 °C - ambient air - 59,5% relative humidity
Setpoint at controller unit 55 °C
Standby power
Acoustic emission (ducted)
(according to EN 12102-1:2017 and EN ISO 9614-2)
HEAT PUMP
Dimensions
Weight without packaging
Weight with full tank
Refrigerant (R290)
Stocking and transport temperature range
ELECTRICAL
Voltage / Frequency
Heat pump input
Heat pump output
Supplementary heating
Fuse protection
Thermostat for supplementary heating
AIR
Air flow
Air temperature
WATER
Boiler, water content
Working pressure
Water temperature
Water capacity
Water connections
Cold water inlet
Hot water outlet
Condensation water
Protection of water ingress
TECHNICAL DATA - VT180C
-
L profile
W
dB(A)
mm
Kg
Kg
Kg
°C
V / Hz
kW
kW
kW
A
°C
m
3
/ h
°C
L
MPa / Bar
°C
L
-
PT
PT
PT
IP
ACCORDING TO EN16147:2017
-
3,20 COP*
6
48
Height: 1576 Width: 540 Depth: 575
70
236
0,150
-20 to +60
230 / 50 Phase - Neutral - Earth
0,344**
1,003**
2,0 / 230 V
10
65, controlled via the display
Min. 100 / Max. 250
Min. -10 to max. +35 or +5 to max. +35 (model specific)
166
1 / 10
Adjustable to max. 62
(mixed water at 40°C), 217
-
3/4” BSP Female
3/4” BSP Female
1/2”
21
* DTI report no. 300-KLAB-18-003 / According to EN16147:2017 / ducted
** According to ASHRAE
ENGLISH
7