7
c
ommissioninG
:
Bowl, tools and Bowl Screen should be cleaned before use – see section on
Cleaning, page 12.
The bowl arms should be at the correct height above the floor before the machine is taken into use – see
Adjustments,
page 5
.
r
ecommended
Use
of
the
machine
:
The machine is designed for the manufacture of products that do not trigger any reactions or release substances
that may be harmful to the user when in use.
The machine must not be used in an explosive atmosphere.
The machine must only be operated by staff who have been trained in the use of the machine according to these
instructions. Users must be over 18 years of age.
The
machine
is designed for commercial use in kitchens, catering outlets and bakeries.
The machine may only be used as specified in this manual.
Only bowls designed for Kodiak 30 may be used. Tools should be used in conjunction with the corresponding bowl – a 30 Q tool
with the 30 Q bowl and a 30/15 Q tool with the 30/15 Q bowl
Unless the change is recommended by the manufacturer, modifying the machine is prohibited.
If the machine is fitted with an attachment drive, only accessories produced or recommended by manufacturer should be attached.
s
afety
:
The machine is designed for the manufacture of products that do not trigger any reactions or release substances
that may be harmful to the user when in use.
Users must be over 18 years of age and trained in the use of the machine according to these instructions.
User safety is assured as follows:
•
Tools can only rotate when the bowl screen is in place and the bowl is lifted.
•
The bowl screen is made of plastic. It is not possible to attach the guard incorrectly.
•
No access to rotating tools.
• The spread of flour dust is inhibited.
•
Equipped with emergency stop - The tool stops rotating in less than 4 seconds (also for normal shut-down and stop via
bowl screen).
•
Clearance between guard/stand and lifting handle at least 1 31/32”.
•
Noise level under 70 dB.
•
Machine remains stable on a slope of up to 10
o
.
The distance from the floor to the bowl arm should be adjusted as shown
in the section on
Adjustments, page 5.
The machine is protected against overvoltage.
Non-ionising radiation is not produced intentionally, but rather technically conditioned by electrical equipment (e.g. electric mo-
tors, live power lines or solenoids). The machine is equipped with strong permanent magnets. By maintaining a safe distance
(between the field source and implant) of 11 13/16”, any impact on active implants (e.g. pacemakers, defibrillators) can likely
be prevented.
The machine should be positioned to allow space for normal use and maintenance.
Good ergonomics for the user is ensured by the accompanying bowl trolley, which eliminates heavy lifting of the bowl and
maintains the right working height.
The following recommendations apply to work with powdery ingredients:
•
Powdery ingredients should not be poured into the bowl from a great height.
• Bags of e.g. flour should be opened at the bottom, down in the bowl.
•
Do not run up to the maximum speed too quickly.
There is a risk of injury if the machine is not earthed.
The machine must only be connected to an earthed mains supply. See also ‘Electrical Connection’ page 6’
.
Placing your hands in the bowl while the machine is running may cause physical injury.
Summary of Contents for V30K
Page 1: ...SPARE PART AND OPERATION MANUAL FOOD MIXER Model V30K May 2019...
Page 17: ...17 Mixer Spare Parts...
Page 21: ...21 14 9 1 4 3 12 13 10 5 7 16 4 2 11 15 8 6...
Page 25: ...25 CR30 10 6Z CR30 50 6Z 7 10 4 5 9 1 13 11 6 5 3 3 8 2 12 14...
Page 32: ...32 14240 South Lakes Drive Charlotte NC 28273 800 222 1138 www varimixerusa com...