14
e
rror
codes
and
possible
solUtions
:
For some errors, the control system will show an error code in the display:
User pressed
without raising the bowl to working height.
Solution
: Raise bowl to working height.
User pressed
without fitting the safety guard.
Solution
: Fit the bowl screen.
The Thermal sensor in the motor has overheated.
Solution
: The error will disappear when the temperature has dropped to an acceptable level.
Stop the mixer and reduce the quantity of ingredients in the bowl. When it starts again, select a lower speed.
There is an error in communication between the control panel and the frequency converter.
Solution:
Call the engineer.
Error in frequency converter.
Solution
: Call the engineer.
Thermal sensor in the frequency converter has cut out.
Solution
: The error will disappear when the temperature has dropped to an acceptable level.
Intermittent low voltage in the power supply.
Solution
: The power supply to the mixer should be checked by an expert.
Intermittent high voltage in the power supply.
Solution
: The power supply to the mixer should be checked by an expert.
The mixer is overloaded - continuously for 50 seconds
Solution
: Reduce the quantity in the bowl; alternatively, the product may need to be divided into smaller parts or diluted before
the machine is restarted. When restarted, select a lower speed, if speed was the problem
The error code is removed by pressing
The mixer is overloaded - momentarily (overloaded 8 times within 20 seconds
Solution
: Reduce the quantity in the bowl; alternatively, the product may need to be divided into smaller parts or diluted before
the machine is restarted. When restarted, select a lower speed, if speed was the problem.
The error code is removed by pressing
Blockage.
Solution
: Remove the object that caused the blockage.
The error code is removed by pressing
,
and
can also occur when using the attachment drive.
Summary of Contents for V30K
Page 1: ...SPARE PART AND OPERATION MANUAL FOOD MIXER Model V30K May 2019...
Page 17: ...17 Mixer Spare Parts...
Page 21: ...21 14 9 1 4 3 12 13 10 5 7 16 4 2 11 15 8 6...
Page 25: ...25 CR30 10 6Z CR30 50 6Z 7 10 4 5 9 1 13 11 6 5 3 3 8 2 12 14...
Page 32: ...32 14240 South Lakes Drive Charlotte NC 28273 800 222 1138 www varimixerusa com...