6
53 13/16”
24 9/16”
22 1/8”
19 7/16”
31 3/16”
m
ax
.
capacity
of
the
machine
:
AR = absorption ratio (%AR)
(liquid as % of dry matter)
E.g.
a basic recipe includes 2.2 lbs dry matter and 1.3 lbs liquid:
this gives
AR
=
1.3 lbs x 100
= 60%
2.2 lbs
If, for example, the maximum capacity of the mixer is required, the calculated AR =
60% is used to determine the amount of dry matter and liquid in the dough:
Maximum capacity of the machine = 28.7 lbs for dough with AR = 60%
Now the weight of the dry matter in this dough is calculated as follows:
Dry matter =
max. capacity x 100 = 28.7 lbs x 100 = 17.9
lbs
AR + 100 60 + 100
Weight of liquid =
28.7 lbs - 17.9 lbs
= 10.8 lbs
Capacity per mix
Tool
KODIAK30
Egg white
Whip
3.17 Qts
Mayonnaise
Whip
21.13 Qts
Yeast dough (60% AR)
Hook
28.7 lbs
Meatball mix
Beater
44.1 lbs
Local variations in the quality of the raw materials may
affect water absorption, volume, baking characteristics
etc., and hence capacity.
e
lectrical
connection
:
Voltage ratio at site
100V - 240V, 1 phase =
User can connect machine
Before the machine is connected to the mains, check that
the voltage and frequency printed on the name plate are
correct for the installation location
.
The name plate is positioned uppermost on the back of the machine.
The machine must be earthed. Failure to do so may cause injury
.
If there is no earth connection, the EMC filter will not work, with the
risk of damage to the frequency converter.
Cable with plug is delivered with the machine
Only this cable must be used for the connection
The machine must only be connected to an
earthed mains supply
T
he cable is fixed to the machine in the plug made of sili
-
cone, see
“
Components of the machine” page 9
The machine is protected by a 10A fuse built into the socket
on the back of the machine.
Voltage ratio at site
380 - 480 V, 2 or 3 phases, neutral or not =
Technician must connect machine
Cable without plug is connected to the machine
the cable must be mounted in the wall socket
The machine must only be connected to an
earthed mains supply
When the machine is connected,
phase + n earth
or
phase + phase + earth
should be used. In both cases,
it is important to ensure that the voltage between the two
live pins matches the name plate.
Gross
weight
485 lbs
Net
weight
418 lbs
HP
1.6
Volts
208V
Amps
8.3A
Variable
speed,
tool
64 – 353 rpm
t
echnical
data
:
NOTE
The machine must be protected
by a Residual Current Device:
Installation in industrial environ-
ment: HPFI type A-SI / PFI type B
Housing, business, light indus-
try: HPFI type A-SI
Summary of Contents for V30K
Page 1: ...SPARE PART AND OPERATION MANUAL FOOD MIXER Model V30K May 2019...
Page 17: ...17 Mixer Spare Parts...
Page 21: ...21 14 9 1 4 3 12 13 10 5 7 16 4 2 11 15 8 6...
Page 25: ...25 CR30 10 6Z CR30 50 6Z 7 10 4 5 9 1 13 11 6 5 3 3 8 2 12 14...
Page 32: ...32 14240 South Lakes Drive Charlotte NC 28273 800 222 1138 www varimixerusa com...